A dose of reality: how 20 years of incomplete physics and dosimetry reporting in radiobiology studies may have contributed to the reproducibility crisis E Draeger, A Sawant, C Johnstone, B Koger, S Becker, Z Vujaskovic, ... International Journal of Radiation Oncology* Biology* Physics 106 (2), 243-252, 2020 | 90 | 2020 |
Multi-institutional MicroCT image comparison of image-guided small animal irradiators CD Johnstone, P Lindsay, EE Graves, E Wong, JR Perez, Y Poirier, ... Physics in Medicine & Biology 62 (14), 5760, 2017 | 19 | 2017 |
Characterization of a plastic scintillating detector for the small animal radiation research platform (SARRP) CD Johnstone, F Therriault‐Proulx, L Beaulieu, M Bazalova‐Carter Medical physics 46 (1), 394-404, 2019 | 18 | 2019 |
Modeling a superficial radiotherapy x‐ray source for relative dose calculations CD Johnstone, R LaFontaine, Y Poirier, M Tambasco Journal of Applied Clinical Medical Physics 16 (3), 118-130, 2015 | 18 | 2015 |
MicroCT imaging dose to mouse organs using a validated Monte Carlo model of the small animal radiation research platform (SARRP) CD Johnstone, M Bazalova-Carter Physics in Medicine & Biology 63 (11), 115012, 2018 | 17 | 2018 |
Monte Carlo optimization of a microbeam collimator design for use on the small animal radiation research platform (SARRP) NM Esplen, L Chergui, CD Johnstone, M Bazalova-Carter Physics in Medicine & Biology 63 (17), 175004, 2018 | 14 | 2018 |
A 3D printed modular phantom for quality assurance of image‐guided small animal irradiators: Design, imaging experiments, and Monte Carlo simulations DY Breitkreutz, S Bialek, B Vojnovic, A Kavanagh, CD Johnstone, ... Medical Physics 46 (5), 2015-2024, 2019 | 9 | 2019 |
The potential impact of ultrathin filter design on dosimetry and relative biological effectiveness in modern image-guided small animal irradiators Y Poirier, CD Johnstone, C Kirkby The British Journal of Radiology 92 (1095), 20180537, 2019 | 7 | 2019 |
A failure modes and effects analysis quality management framework for image‐guided small animal irradiators: A change in paradigm for radiation biology Y Poirier, CD Johnstone, A Anvari, NP Brodin, MD Santos, ... Medical physics 47 (4), 2013-2022, 2020 | 5 | 2020 |
Impact of Inter-and Intra-Fraction Motion on Delivered Dose for Prostate SBRT Patients Treated on an MRL-Linac Using a Novel Semi-Automated Dose Accumulation Framework J Winter, CD Johnstone, V Kong, J Dang, P Chung, J Padayachee, ... International Journal of Radiation Oncology, Biology, Physics 111 (3), e152-e153, 2021 | 1 | 2021 |
DUOX2, a New Biomarker for Disseminated Gastric Cancer’s Response to Low Dose Radiation in Mice PR Parekh, E Solano-Gonzalez, MB Martins, X Ma, K Tighe, A Casildo, ... Cancers 13 (16), 4186, 2021 | 1 | 2021 |
Commissioning of An Xstrahl SARRP in the Novel Micro-RayStation Treatment Planning System Y Poirier, A Anvari, R Nilsson, A Gerry, C Johnstone, A Sawant MEDICAL PHYSICS 47 (6), E722-E722, 2020 | 1 | 2020 |
A review of small animal dosimetry techniques: image-guided and spatially fractionated therapy CD Johnstone, M Bazalova-Carter Journal of Physics: Conference Series 2630 (1), 012013, 2023 | | 2023 |
Dose Accumulation Comparison Between Adapt-To-Shape and Adapt-To-Position for MRL Adaptive SBRT Prostate Patients CD Johnstone, T Tadic, V Malkov, D Letourneau, J Winter MEDICAL PHYSICS 48 (6), 2021 | | 2021 |
Investigating chemopotentiation by low-dose fractionated radiation therapy for disseminated intra-abdominal gastric cancer. F Carrier, P Parekh, E Solano-Gonzalez, X Ma, K Tighe, A Casildo, ... Journal of Clinical Oncology 39 (3_suppl), 242-242, 2021 | | 2021 |
DUOX2, a New Biomarker for Disseminated Gastric Cancer’s Response to Low Dose Radiation in Mice. Cancers 2021, 13, 4186 PR Parekh, E Solano-Gonzalez, MB Martins, X Ma, K Tighe, A Casildo, ... s Note: MDPI stays neutral with regard to jurisdictional claims in published …, 2021 | | 2021 |
The Impact of Radiation Energy on Dose Homogeneity and Organ Dose in the Göttingen Minipig Total-Body Irradiation Model Y Poirier, S Becker, C Decesaris, W Culberson, E Draeger, AJ Gerry, ... Radiation Research 194 (5), 544-556, 2020 | | 2020 |
Two Decades of Physics and Dosimetry Reporting in Radiobiological Studies: A Potential Factor of the Reproducibility Crisis E Draeger, A Sawant, C Johnstone, B Koger, S Becker, Z Vujaskovic, ... MEDICAL PHYSICS 46 (6), E175-E175, 2019 | | 2019 |
Microcomputed tomography dosimetry and image quality in preclinical image-guided radiation therapy CD Johnstone | | 2019 |
3D Printed Phantom for MicroCT Imaging QA S Bialek, B Vojanovic, A Kavanagh, C Johnstone, T Kanesalingam, ... MEDICAL PHYSICS 45 (6), E421-E421, 2018 | | 2018 |