On stabilized space‐time FEM for anisotropic meshes: incompressible Navier–Stokes equations and applications to blood flow in medical devices L Pauli, M Behr International Journal for Numerical Methods in Fluids 85 (3), 189-209, 2017 | 60 | 2017 |
Transient stress‐based and strain‐based hemolysis estimation in a simplified blood pump L Pauli, J Nam, M Pasquali, M Behr International journal for numerical methods in biomedical engineering 29 (10 …, 2013 | 56 | 2013 |
Towards shape optimization of profile extrusion dies with respect to homogeneous die swell L Pauli, M Behr, S Elgeti Journal of Non-Newtonian Fluid Mechanics 200, 79-87, 2013 | 51 | 2013 |
Consistent formulation of the growth process at the kinematic and constitutive level for soft tissues composed of multiple constituents H Schmid, L Pauli, A Paulus, E Kuhl, M Itskov Computer methods in biomechanics and biomedical engineering 15 (5), 547-561, 2012 | 35* | 2012 |
Stabilized finite element methods for computational design of blood-handling devices L Pauli Verlag Dr. Hut, 2016 | 23 | 2016 |
Strain-based blood damage estimation for computational design of ventricular assist devices L Gesenhues, L Pauli, M Behr The International journal of artificial organs 39 (4), 166-170, 2016 | 17 | 2016 |
On the usage of NURBS as interface representation in free‐surface flows S Elgeti, H Sauerland, L Pauli, M Behr International journal for numerical methods in fluids 69 (1), 73-87, 2012 | 16 | 2012 |
The virtual ring shear-slip mesh update method F Key, L Pauli, S Elgeti Computers & Fluids 172, 352-361, 2018 | 15 | 2018 |
Stabilized finite element method for flows with multiple reference frames L Pauli, JW Both, M Behr International Journal for Numerical Methods in Fluids 78 (11), 657-669, 2015 | 14 | 2015 |
The variational multiscale formulation for the fully‐implicit log‐morphology equation as a tensor‐based blood damage model S Haßler, L Pauli, M Behr International Journal for Numerical Methods in Biomedical Engineering 35 (12 …, 2019 | 8 | 2019 |
Computational fluid dynamics for mechanical circulatory support device development R Graefe, L Pauli Mechanical Support for Heart Failure: Current Solutions and New Technologies …, 2020 | 3 | 2020 |
On the significance of exposure time in computational blood damage estimation L Pauli, M Behr High-Performance Scientific Computing: First JARA-HPC Symposium, JHPCS 2016 …, 2017 | 3 | 2017 |
Simulating die swell in the context of profile extrusion L Pauli, M Behr Master Thesis. Rwthaachen University, 2011 | 2 | 2011 |
An eigenvalue-free implementation of the log-conformation formulation F Becker, K Rauthmann, L Pauli, P Knechtges Journal of Non-Newtonian Fluid Mechanics 322, 105133, 2023 | 1 | 2023 |
Robustness and Performance of Logarithm-Conformation Methods for Viscoelastic Flow Problems F Becker, P Knechtges, L Pauli, K Rauthman Computational Fluids Conference 2023, 2023 | | 2023 |
An Enhanced Time-Discontinuous Galerkin Method for Rotating Geometries such as Artificial Blood Pumps S Haßler, L Pauli, M Behr Book of Abstracts-Extract, 7, 2015 | | 2015 |
Unsteady Blood Damage Estimation for Medical Devices L Pauli, J Nam, M Pasquali, M Behr The MATHCARD EU Project-www. mathcard. eu, Chia Laguna, Domus de Maria …, 2013 | | 2013 |
On the Improvement of a Physiological Blood Damage Model for Hemolysis Predictions in Medical Devices S Haßler, L Pauli, M Behr | | |
Improving Numerical Stability of a Tensor-Based Blood Damage Model using the Log-Conformation Formulation S Haßler, L Pauli, M Behr | | |
How the deformation of red blood cells affects hemolysis estimation for ventricular assist devices L Pauli, S Haßler, M Behr | | |