关注
Frans van der Helm
Frans van der Helm
Professor in Biomechatronics and Biorobotics, TU Delft
在 tudelft.nl 的电子邮件经过验证
标题
引用次数
引用次数
年份
ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion—Part II: shoulder, elbow, wrist and hand
G Wu, FCT Van der Helm, HEJDJ Veeger, M Makhsous, P Van Roy, ...
Journal of biomechanics 38 (5), 981-992, 2005
40392005
A finite element musculoskeletal model of the shoulder mechanism
FCT Van der Helm
Journal of biomechanics 27 (5), 551-569, 1994
6701994
Morphological muscle and joint parameters for musculoskeletal modelling of the lower extremity
MDK Horsman, HFJM Koopman, FCT van der Helm, LP Prosé, ...
Clinical biomechanics 22 (2), 239-247, 2007
5442007
Shoulder function: the perfect compromise between mobility and stability
HEJ Veeger, FCT Van Der Helm
Journal of biomechanics 40 (10), 2119-2129, 2007
5332007
A series elastic-and bowden-cable-based actuation system for use as torque actuator in exoskeleton-type robots
JF Veneman, R Ekkelenkamp, R Kruidhof, FCT van der Helm, ...
The international journal of robotics research 25 (3), 261-281, 2006
5302006
Kinematic design to improve ergonomics in human machine interaction
A Schiele, FCT Van Der Helm
IEEE Transactions on neural systems and rehabilitation engineering 14 (4 …, 2006
4612006
Analysis of the kinematic and dynamic behavior of the shoulder mechanism
FCT Van der Helm
Journal of biomechanics 27 (5), 527-550, 1994
4551994
Requirements for upper extremity motions during activities of daily living
DJ Magermans, EKJ Chadwick, HEJ Veeger, FCT Van Der Helm
Clinical biomechanics 20 (6), 591-599, 2005
4432005
Inertia and muscle contraction parameters for musculoskeletal modelling of the shoulder mechanism
HEJ Veeger, FCT Van Der Helm, LHV Van Der Woude, GM Pronk, ...
Journal of biomechanics 24 (7), 615-629, 1991
3751991
Three-dimensional recording and description of motions of the shoulder mechanism
FCT van der Helm, GM Pronk
3671995
Magnetic distortion in motion labs, implications for validating inertial magnetic sensors
WHK De Vries, HEJ Veeger, CTM Baten, FCT Van Der Helm
Gait & posture 29 (4), 535-541, 2009
3382009
Geometry parameters for musculoskeletal modelling of the shoulder system
FCT Van der Helm, HEJ Veeger, GM Pronk, LHV Van der Woude, ...
Journal of biomechanics 25 (2), 129-144, 1992
3291992
3D shoulder position measurements using a six-degree-of-freedom electromagnetic tracking device
CGM Meskers, HM Vermeulen, JH De Groot, FCT Van der Helm, ...
Clinical biomechanics 13 (4-5), 280-292, 1998
3231998
In vivo estimation of the glenohumeral joint rotation center from scapular bony landmarks by linear regression
CGM Meskers, FCT Van der Helm, LA Rozendaal, PM Rozing
Journal of biomechanics 31 (1), 93-96, 1997
3091997
International Society of Biomechanics. ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion—part II …
G Wu, FC Van der Helm, HE Veeger, M Makhsous, P Van Roy, C Anglin, ...
J Biomech 38 (5), 981-92, 2005
3072005
An adaptive model of sensory integration in a dynamic environment applied to human stance control
H van der Kooij, R Jacobs, B Koopman, F van der Helm
Biological cybernetics 84, 103-115, 2001
3052001
How to keep from falling forward: Elementary swing leg action for passive dynamic walkers
M Wisse, AL Schwab, RQ van der Linde, FCT van der Helm
IEEE Transactions on robotics 21 (3), 393-401, 2005
2892005
Self-aligning exoskeleton axes through decoupling of joint rotations and translations
AHA Stienen, EEG Hekman, FCT Van Der Helm, H Van Der Kooij
IEEE Transactions on Robotics 25 (3), 628-633, 2009
2702009
Comparison of different methods to identify and quantify balance control
H van der Kooij, E van Asseldonk, FCT van der Helm
Journal of neuroscience methods 145 (1-2), 175-203, 2005
2502005
Calibration of the “Flock of Birds” electromagnetic tracking device and its application in shoulder motion studies
CGM Meskers, H Fraterman, FCT Van der Helm, HM Vermeulen, ...
Journal of biomechanics 32 (6), 629-633, 1999
2441999
系统目前无法执行此操作,请稍后再试。
文章 1–20