A survey on robotic devices for upper limb rehabilitation P Maciejasz, J Eschweiler, K Gerlach-Hahn, A Jansen-Troy, S Leonhardt Journal of neuroengineering and rehabilitation 11, 1-29, 2014 | 1306 | 2014 |
Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy … I Frerichs, MBP Amato, AH Van Kaam, DG Tingay, Z Zhao, B Grychtol, ... Thorax 72 (1), 83-93, 2017 | 789 | 2017 |
Neonatal non-contact respiratory monitoring based on real-time infrared thermography AK Abbas, K Heimann, K Jergus, T Orlikowsky, S Leonhardt Biomedical engineering online 10, 1-17, 2011 | 282 | 2011 |
Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography T Meier, H Luepschen, J Karsten, T Leibecke, M Großherr, H Gehring, ... Intensive care medicine 34, 543-550, 2008 | 272 | 2008 |
Adaptive beat-to-beat heart rate estimation in ballistocardiograms C Bruser, K Stadlthanner, S de Waele, S Leonhardt IEEE Transactions on Information Technology in Biomedicine 15 (5), 778-786, 2011 | 266 | 2011 |
Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring? S Leonhardt, B Lachmann Intensive care medicine 38, 1917-1929, 2012 | 233 | 2012 |
Methods of fault diagnosis S Leonhardt, M Ayoubi Control engineering practice 5 (5), 683-692, 1997 | 231 | 1997 |
Characterization of textile electrodes and conductors using standardized measurement setups L Beckmann, C Neuhaus, G Medrano, N Jungbecker, M Walter, T Gries, ... Physiological measurement 31 (2), 233, 2010 | 224 | 2010 |
Automatic step detection in the accelerometer signal H Ying, C Silex, A Schnitzer, S Leonhardt, M Schiek 4th International Workshop on Wearable and Implantable Body Sensor Networks …, 2007 | 210 | 2007 |
Ventilation system S Leonhardt, E Teschner US Patent 7,162,296, 2007 | 209 | 2007 |
Remote monitoring of breathing dynamics using infrared thermography CB Pereira, X Yu, M Czaplik, R Rossaint, V Blazek, S Leonhardt Biomedical optics express 6 (11), 4378-4394, 2015 | 184 | 2015 |
Ambient and unobtrusive cardiorespiratory monitoring techniques C Brüser, CH Antink, T Wartzek, M Walter, S Leonhardt IEEE reviews in biomedical engineering 8, 30-43, 2015 | 174 | 2015 |
Methods for engine supervision and control based on cylinder pressure information S Leonhardt, N Muller, R Isermann IEEE/ASME transactions on mechatronics 4 (3), 235-245, 1999 | 167 | 1999 |
Tidal recruitment assessed by electrical impedance tomography and computed tomography in a porcine model of lung injury T Muders, H Luepschen, J Zinserling, S Greschus, R Fimmers, ... Critical care medicine 40 (3), 903-911, 2012 | 164 | 2012 |
Blood glucose control algorithms for type 1 diabetic patients: A methodological review K Lunze, T Singh, M Walter, MD Brendel, S Leonhardt Biomedical signal processing and control 8 (2), 107-119, 2013 | 162 | 2013 |
The smart car seat: Personalized monitoring of vital signs in automotive applications M Walter, B Eilebrecht, T Wartzek, S Leonhardt Personal and Ubiquitous Computing 15, 707-715, 2011 | 152 | 2011 |
Wireless and non-contact ECG measurement system–the “Aachen SmartChair” A Aleksandrowicz, S Leonhardt Acta Polytechnica 47 (4-5), 2007 | 152 | 2007 |
ECG on the road: Robust and unobtrusive estimation of heart rate T Wartzek, B Eilebrecht, J Lem, HJ Lindner, S Leonhardt, M Walter IEEE Transactions on biomedical engineering 58 (11), 3112-3120, 2011 | 150 | 2011 |
Mobile noncontact monitoring of heart and lung activity M Steffen, A Aleksandrowicz, S Leonhardt IEEE Transactions on Biomedical Circuits and Systems 1 (4), 250-257, 2007 | 146 | 2007 |
Robust inter-beat interval estimation in cardiac vibration signals C Brüser, S Winter, S Leonhardt Physiological measurement 34 (2), 123, 2013 | 145 | 2013 |