An electrochemical method for the preparation of 63Ni source for the calibration of thermo luminescence dosimeter (TLD) ADMV Manoj Kumar, J.Udhayakumar, Shyamala S. Gandhi Applied Radiation and Isotopes, 67, 1042-1049, 2009 | 26 | 2009 |
“Development of technology for the large-scale preparation of 60Co polymer film source” MV J. Udhayakumar, G.S. Pardeshi, Shyamala S. Gandhi, Rubel Chakravarty ... Applied Radiation and Isotopes 66 (12), 1825-1829, 2008 | 16 | 2008 |
On the application of electrochemical techniques for the preparation of 57Co source core, encapsulation and quality evaluation for radiometric assay of nuclear fuel rods MVVV Ashutosh Dash, Manoj Kumar, J.Udhayakumar, Shyamala S. Gandhi, A.K ... Radiochimica Acta 99, 103-111, 2011 | 12 | 2011 |
Development of a 147Pm source for beta-backscatter thickness gauge applications ADMV Manoj Kumar, J.Udhayakumar, J.Nuwad, Rakesh Sukla, C.G.S Pillai Applied Radiation and Isotopes 69, 580-587, 2011 | 12 | 2011 |
Preparation of spherical 57Co source for the calibration of Intra- operative gamma probe ADMV J.Udhayakumar Manoj Kumar, Shyamala S. Gandhi, B. S. Tomar Applied radiation and Isotopes 70, 167-170, 2012 | 10 | 2012 |
Development of a micro electrochemical cell for in-situ deposition of 63Ni for use in electron capture detector (ECD) in gas chromatography MV Ashutosh Dash, J.Udhayakumar, Manoj Kumar, Rakesh Shukla, Shyamala S ... Radiochimica Acta 99, 733-741, 2011 | 10 | 2011 |
A novel method for the preparation of large-area 90Sr/90Y sources for the calibration of hand contamination monitors AD Manoj Kumar, Shyamala S. Gandhi, Rubel Chakravarty, J. Nuwad, J. Udhayakumar Applied radiation and Isotopes, 5-11, 2013 | 8 | 2013 |
Selective area chemical-deposition process: An innovative and facile route to prepare 147Pm source for dust monitors ATAD Manoj Kumar, Rakesh Shukla, Shyamala S. Gandhi, J. Udhayakumar Industrial & Engineering Chemistry Research, 11147-11156, 2012 | 7 | 2012 |
Preparation of 57Co point sources for the performance evaluation of nuclear imaging instruments AD Sanjay Kumar Saxena, Manoj Kumar, Yogendra Kumar, J. Udhayakumar, Usha Pandey Applied radiation and Isotopes, 12-17, 2013 | 5 | 2013 |
A novel and facile approach for the preparation of 133Ba source core, encapsulation and quality evaluation AD Manoj Kumar, Shyamala S. Gandhi, J. Nuwad, J. Udhayakumar Radiochimica Acta 101, 195-203, 2013 | 5 | 2013 |
An electrochemical technique to prepare 55Fe source for the calibration of the X-ray Detectors AKTAD Manoj Kumar, Shyamala S. Gandhi, J. Udhayakumar, A. K. Satpati, R. Shukla Radiochimica Acta 101, 185-193, 2013 | 5 | 2013 |
An electrochemical route to prepare planar 204Tl sources for the calibration of beta surface contamination monitors JUAD S. S. Gandhi, M.Kumar, R. Chakravarty, J.Nuwad Radiochimica Acta 101, 427-436, 2013 | 4* | 2013 |
A chemical deposition method to prepare circular planar 147Pm sources for the measurement of particulate emission in air AD J.Udhayakumar, Shyamala S.Gandhi, Manoj Kumar Applied radiation and Isotopes 79, 80-84, 2013 | 3 | 2013 |
Development of 57Co Pen Pointer Marker Source for Applications in Nuclear Medicine Procedures AD Manoj Kumar, Shyamala S. Gandhi, J. Udhayakumar* Nuclear and Radiochemistry Symposium(NUCAR), 462-463, 2015 | 1* | 2015 |
Quality assurance and classification performance testing of I-125-brachytherapy seeds ADMV S. K. Saxena, Yogendra Kumar, Manoj Kumar International Conference on Medical Physics( ICMP), 49-50, 2008 | 1* | 2008 |
Cadmium-109 Custom X-ray Source for Astronomical Applications AD J.Udhayakumar, Manoj Kumar, Shyamala S. Gandhi Nuclear and Radiochemistry Symposium(NUCAR), 464-465, 2015 | | 2015 |
Development of Multi Dimensional 90Sr/90Y Thin Film Sources AD Shyamala S. Gandhi, Manoj Kumar, J. Udhayakumar* 5th International Symposium on Material Chemistry, 334, 2014 | | 2014 |
An elecrochemical pathway to prepare circular planar 90Sr/90Y source for the calibration of surface contamination monitor AD Manoj Kumar, Shyamala S. Gandhi, J. Nuwad, J. Udhayakumar J Radioanal Nucl Chem 302, 709-719, 2014 | | 2014 |
Utilization of anodized aluminium surface as a substrate for the preparation of 147Pm source for dust monitor JUAD Shyamala S. Gandhi, Manoj Kumar ISEAC International Symposium cum Workshop on Electrochemistry, 156-159, 2011 | | 2011 |
Development of a micro electrochemical cell for the deposition of 63Ni for use as an ionization source in electron capture detector (ECD) of gas chromatography MKADMV J.Udhayakumar 7th International Conference on Isotopes (ICI), 128, 2011 | | 2011 |