Matching material and cellular timescales maximizes cell spreading on viscoelastic substrates Z Gong, SE Szczesny, SR Caliari, EE Charrier, O Chaudhuri, X Cao, Y Lin, ... Proceedings of the National Academy of Sciences 115 (12), E2686-E2695, 2018 | 242 | 2018 |
Interfibrillar shear stress is the loading mechanism of collagen fibrils in tendon SE Szczesny, DM Elliott Acta biomaterialia 10 (6), 2582-2590, 2014 | 194 | 2014 |
Biaxial tensile testing and constitutive modeling of human supraspinatus tendon SE Szczesny, JM Peloquin, DH Cortes, JA Kadlowec, LJ Soslowsky, ... | 96 | 2012 |
The Nuclear Option: Evidence Implicating the Cell Nucleus in Mechanotransduction SE Szczesny, RL Mauck Journal of Biomechanical Engineering 139 (2), 021006, 2017 | 75 | 2017 |
Mechanically induced chromatin condensation requires cellular contractility in mesenchymal stem cells SJ Heo, WM Han, SE Szczesny, BD Cosgrove, DM Elliott, DA Lee, ... Biophysical journal 111 (4), 864-874, 2016 | 71 | 2016 |
Investigating mechanisms of tendon damage by measuring multi-scale recovery following tensile loading AH Lee, SE Szczesny, MH Santare, DM Elliott Acta biomaterialia 57, 363-372, 2017 | 67 | 2017 |
Quantification of interfibrillar shear stress in aligned soft collagenous tissues via notch tension testing SE Szczesny, JL Caplan, P Pedersen, DM Elliott Scientific reports 5 (1), 14649, 2015 | 64 | 2015 |
Experimental and computational investigation of altered mechanical properties in myocardium after hydrogel injection ET Kichula, H Wang, SM Dorsey, SE Szczesny, DM Elliott, JA Burdick, ... Annals of biomedical engineering 42, 1546-1556, 2014 | 63 | 2014 |
Regional variation in human supraspinatus tendon proteoglycans: decorin, biglycan, and aggrecan PE Matuszewski, YL Chen, SE Szczesny, SP Lake, DM Elliott, ... Connective tissue research 53 (5), 343-348, 2012 | 61 | 2012 |
Evidence that interfibrillar load transfer in tendon is supported by small diameter fibrils and not extrafibrillar tissue components SE Szczesny, KL Fetchko, GR Dodge, DM Elliott Journal of Orthopaedic Research 35 (10), 2127-2134, 2017 | 60 | 2017 |
Biaxial mechanics and inter‐lamellar shearing of stem‐cell seeded electrospun angle‐ply laminates for annulus fibrosus tissue engineering TP Driscoll, RH Nakasone, SE Szczesny, DM Elliott, RL Mauck Journal of orthopaedic research 31 (6), 864-870, 2013 | 60 | 2013 |
Cross-linking chemistry of tyramine-modified hyaluronan hydrogels alters mesenchymal stem cell early attachment and behavior C Loebel, SE Szczesny, BD Cosgrove, M Alini, M Zenobi-Wong, ... Biomacromolecules 18 (3), 855-864, 2017 | 58 | 2017 |
Incorporating plasticity of the interfibrillar matrix in shear lag models is necessary to replicate the multiscale mechanics of tendon fascicles SE Szczesny, DM Elliott Journal of the mechanical behavior of biomedical materials 40, 325-338, 2014 | 57 | 2014 |
Crimped nanofibrous biomaterials mimic microstructure and mechanics of native tissue and alter strain transfer to cells SE Szczesny, TP Driscoll, HY Tseng, PC Liu, SJ Heo, RL Mauck, ... ACS biomaterials science & engineering 3 (11), 2869-2876, 2017 | 51 | 2017 |
Exposure to buffer solution alters tendon hydration and mechanics BN Safa, KD Meadows, SE Szczesny, DM Elliott Journal of biomechanics 61, 18-25, 2017 | 46 | 2017 |
Fatigue loading of tendon results in collagen kinking and denaturation but does not change local tissue mechanics SE Szczesny, C Aeppli, A David, RL Mauck Journal of biomechanics 71, 251-256, 2018 | 44 | 2018 |
Macroporous hydrogels for stable sequestration and sustained release of vascular endothelial growth factor and basic fibroblast growth factor using nucleic acid aptamers L Abune, N Zhao, J Lai, B Peterson, S Szczesny, Y Wang ACS biomaterials science & engineering 5 (5), 2382-2390, 2019 | 39 | 2019 |
Expansion of mesenchymal stem cells on electrospun scaffolds maintains stemness, mechano‐responsivity, and differentiation potential SJ Heo, SE Szczesny, DH Kim, KS Saleh, RL Mauck Journal of Orthopaedic Research® 36 (2), 808-815, 2018 | 38 | 2018 |
Altered lumbar spine structure, biochemistry, and biomechanical properties in a canine model of mucopolysaccharidosis type VII LJ Smith, JT Martin, SE Szczesny, KP Ponder, ME Haskins, DM Elliott Journal of Orthopaedic Research 28 (5), 616-622, 2010 | 34 | 2010 |
DTAF dye concentrations commonly used to measure microscale deformations in biological tissues alter tissue mechanics SE Szczesny, RS Edelstein, DM Elliott PloS one 9 (6), e99588, 2014 | 33 | 2014 |