关注
Guilherme Carrilho da Graça
Guilherme Carrilho da Graça
Associate Professor University of Lisbon
在 fc.ul.pt 的电子邮件经过验证 - 首页
标题
引用次数
引用次数
年份
Validation of EnergyPlus thermal simulation of a double skin naturally and mechanically ventilated test cell
NM Mateus, A Pinto, GC Da Graça
Energy and Buildings 75, 511-522, 2014
2612014
Impact of PM2. 5 in indoor urban environments: A review
NR Martins, GC Da Graca
Sustainable Cities and Society 42, 259-275, 2018
2332018
Simulation of wind-driven ventilative cooling systems for an apartment building in Beijing and Shanghai
G Carrilho da Graca, Q Chen, LR Glicksman, LK Norford
Energy and buildings 34 (1), 1-11, 2002
1612002
Ten questions about natural ventilation of non-domestic buildings
GC da Graça, P Linden
Building and Environment 107, 263-273, 2016
1452016
Solar powered net zero energy houses for southern Europe: Feasibility study
G Carrilho da Graca, A Augusto, M Lerer
Solar Energy, 2011
141*2011
Impact of outdoor PM2. 5 on natural ventilation usability in California’s nondomestic buildings
NR Martins, GC da Graça
Applied energy 189, 711-724, 2017
822017
Thermal and Airflow Simulation of a Naturally Ventilated Shopping Mall
GC Graça, NR Martins, CS Horta
Energy and Buildings, 2012
772012
Impact of aperture separation on wind-driven single-sided natural ventilation
NC Daish, GC da Graça, PF Linden, D Banks
Building and Environment 108, 122-134, 2016
642016
Comparison of methodologies for generation of future weather data for building thermal energy simulation
JB Dias, GC da Graca, PMM Soares
Energy and Buildings 206, 109556, 2020
612020
Design and testing of a control strategy for a large, naturally ventilated office building
GC da Graca, PF Linden, P Haves
Building Services Engineering Research and Technology 25 (3), 223-239, 2004
602004
A validated three-node model for displacement ventilation
NM Mateus, GC da Graça
Building and Environment 84, 50-59, 2015
592015
Measured and modeled performance of internal mass as a thermal energy battery for energy flexible residential buildings
MJNO Panão, NM Mateus, GC Da Graça
Applied Energy 239, 252-267, 2019
572019
Validation of numerical simulation tools for wind-driven natural ventilation design
NR Martins, GC da Graça
Building Simulation, 1-13, 2015
562015
Validation of a lumped RC model for thermal simulation of a double skin natural and mechanical ventilated test cell
MJNO Panão, CAP Santos, NM Mateus, GC da Graça
Energy and Buildings 121, 92-103, 2016
542016
Simulated and measured performance of displacement ventilation systems in large rooms
NM Mateus, GC da Graça
Building and Environment 114, 470-482, 2017
532017
Comparison between geothermal district heating and deep energy refurbishment of residential building districts
JF Pinto, GC da Graça
Sustainable cities and society 38, 309-324, 2018
472018
Full-scale measurement and validated simulation of cooling load reduction due to nighttime natural ventilation of a large atrium
DP Albuquerque, N Mateus, M Avantaggiato, GC da Graça
Energy and Buildings 224, 110233, 2020
452020
Simulation of the effect of fine particle pollution on the potential for natural ventilation of non-domestic buildings in European cities
NR Martins, GC da Graça
Building and Environment 115, 236-250, 2017
442017
Comparison of measured and simulated performance of natural displacement ventilation systems for classrooms
NM Mateus, GN Simoes, C Lúcio, GC da Graca
Energy and Buildings 133, 185-196, 2016
382016
The effect of typical buoyant flow elements and heat load combinations on room air temperature profile with displacement ventilation
R Kosonen, N Lastovets, P Mustakallio, GC da Graça, NM Mateus, ...
Building and Environment 108, 207-219, 2016
362016
系统目前无法执行此操作,请稍后再试。
文章 1–20