Monte Carlo characterization of an ytterbium‐169 high dose rate brachytherapy source with analysis of statistical uncertainty DC Medich, MA Tries, JJ Munro III Medical physics 33 (1), 163-172, 2006 | 96 | 2006 |
Thermal noise reduction of mechanical oscillators by actively controlled external dissipative forces S Liang, D Medich, DM Czajkowsky, S Sheng, JY Yuan, Z Shao Ultramicroscopy 84 (1-2), 119-125, 2000 | 76 | 2000 |
The use of new EBT film for seed dosimetry in Solid phantom ST Chiu‐Tsao, D Medich, J Munro III Medical physics 35 (8), 3787-3799, 2008 | 64 | 2008 |
Monte Carlo characterization of the M‐19 high dose rate Iridium‐192 brachytherapy source DC Medich, JJ Munro III Medical physics 34 (6Part1), 1999-2006, 2007 | 35 | 2007 |
Monte Carlo characterization of a new Yb‐169 high dose rate source for brachytherapy application MJ Cazeca, DC Medich, JJ Munro III Medical physics 37 (3), 1129-1136, 2010 | 34 | 2010 |
Radioisotopes and vertebral augmentation: dosimetric analysis of a novel approach for the treatment of malignant compression fractures AE Hirsch, DC Medich, BS Rosenstein, CB Martel, JA Hirsch Radiotherapy and Oncology 87 (1), 119-126, 2008 | 33 | 2008 |
Introduction to radiation safety and monitoring JJ Cuaron, AE Hirsch, DC Medich, JA Hirsch, BS Rosenstein Journal of the American College of Radiology 8 (4), 259-264, 2011 | 30 | 2011 |
Comparison of methods to estimate water‐equivalent diameter for calculation of patient dose A Daudelin, D Medich, SY Andrabi, C Martel Journal of Applied Clinical Medical Physics 19 (5), 718-723, 2018 | 27 | 2018 |
Polymethylmethacrylate and radioisotopes in vertebral augmentation: an explanation of underlying principles AE Hirsch, BS Rosenstein, DC Medich, CB Martel, JA Hirsch Pain Physician 12 (5), 887, 2009 | 21 | 2009 |
A proposed methodology to select radioisotopes for use in radionuclide therapy JJ Cuaron, JA Hirsch, DC Medich, BS Rosenstein, CB Martel, AE Hirsch American journal of neuroradiology 30 (10), 1824-1829, 2009 | 19 | 2009 |
Dependence of Yb‐169 absorbed dose energy correction factors on self‐attenuation in source material and photon buildup in water DC Medich, JJ Munro III Medical physics 37 (5), 2135-2144, 2010 | 18 | 2010 |
Changes in occupational radiation exposures after incorporation of a real-time dosimetry system in the interventional radiology suite S Poudel, L Weir, D Dowling, DC Medich Health Physics 111 (2), S166-S171, 2016 | 12 | 2016 |
X-ray emitting sources and uses thereof JJ Munro III, DC Medich US Patent 6,400,796, 2002 | 12 | 2002 |
Intraoperative high-dose-rate brachytherapy using 170thulium radiation sources JJ Munro, DC Medich, S Mutyala Brachytherapy 7 (2), 160, 2008 | 11 | 2008 |
Shielded high dose rate ocular brachytherapy using Yb-169 JM Dupere, JJ Munro, DC Medich Physics in Medicine & Biology 66 (12), 125003, 2021 | 9 | 2021 |
Dosimetric characterization of the GammaClip™ 169Yb low dose rate permanent implant brachytherapy source for the treatment of nonsmall cell lung cancer … B Currier, JJ Munro III, DC Medich Medical Physics 40 (8), 080701, 2013 | 9 | 2013 |
Effects of breast‐air and breast‐lung interfaces on the dose rate at the planning target volume of a MammoSite® catheter for Yb‐169 and Ir‐192 HDR sources MJ Cazeca, DC Medich, JJ Munro III Medical physics 37 (8), 4038-4045, 2010 | 9 | 2010 |
Monte Carlo dosimetric characterization of a new high dose rate Yb brachytherapy source and independent verification using a multipoint plastic scintillator detector G Famulari, HM Linares Rosales, J Dupere, DC Medich, L Beaulieu, ... Medical Physics 47 (9), 4563-4573, 2020 | 7 | 2020 |
Reassessment of resuspension factor following radionuclide dispersal: toward a general-purpose rate constant S Marshall, C Potter, D Medich Health Physics 114 (5), 500-506, 2018 | 7 | 2018 |
Monte Carlo calculated TG‐43 dosimetry parameters for the SeedLink™ brachytherapy system DC Medich, JJ Munro III Medical Physics 30 (9), 2503-2508, 2003 | 7 | 2003 |