Monte Carlo calculation of dose rate distributions around wires F Ballester, C Hernández, J Pérez‐Calatayud, F Lliso Medical physics 24 (8), 1221-1228, 1997 | 91 | 1997 |
Dosimetric characteristics of a new unit for electronic skin brachytherapy T Garcia-Martinez, JP Chan, J Perez-Calatayud, F Ballester Journal of Contemporary Brachytherapy 6 (1), 45-53, 2014 | 62 | 2014 |
Monte Carlo calculations of dose rate distributions around the Amersham CDCS‐M‐type source E Casal, F Ballester, JL Lluch, J Pérez‐Calatayud, F Lliso Medical Physics 27 (1), 132-140, 2000 | 40 | 2000 |
Monte Carlo dosimetry of the Buchler high dose rate 192Ir source F Ballester, J Pérez-Calatayud, V Puchades, JL Lluch, ... Physics in Medicine & Biology 46 (3), N79, 2001 | 32 | 2001 |
Commissioning and initial experience with a commercial software for in vivo volumetric dosimetry J Gimeno, MC Pujades, T García, V Carmona, F Lliso, R Palomo, ... Physica Medica 30 (8), 954-959, 2014 | 31 | 2014 |
Fitted dosimetric parameters of high dose‐rate sources according to the AAPM TG43 formalism F Lliso, J Pérez‐Calatayud, V Carmona, F Ballester, JL Lluch, MA Serrano, ... Medical physics 28 (4), 654-660, 2001 | 31 | 2001 |
A Monte Carlo investigation of the dosimetric characteristics of the CSM11 source from CIS F Ballester, JL Lluch, Y Limami, MA Serrano, E Casal, J Pérez‐Calatayud, ... Medical Physics 27 (9), 2182-2189, 2000 | 27 | 2000 |
Organ contouring for prostate cancer: interobserver and internal organ motion variability X Gual-Arnau, MV Ibanez-Gual, F Lliso, S Roldan Computerized Medical Imaging and Graphics 29 (8), 639-647, 2005 | 25 | 2005 |
Physics Contributions Dosimetric evaluation of internal shielding in a High Dose Rate skin applicator F Lliso, D Granero, J Perez-Calatayud, V Carmona, MC Pujades, ... Journal of Contemporary Brachytherapy 3 (1), 32-38, 2011 | 20 | 2011 |
Failure mode and effects analysis of skin electronic brachytherapy using Esteya® unit B Ibanez-Rosello, JA Bautista-Ballesteros, J Bonaque, F Celada, F Lliso, ... Journal of Contemporary Brachytherapy 8 (6), 518-524, 2016 | 18 | 2016 |
Impact of the Tiloop Bra mesh in CT images and dose delivery in breast radiotherapy C Camacho, J Perez‐Calatayud, F Lliso, V Carmona, A Tormo, F Ballester, ... Journal of applied clinical medical physics 13 (2), 13-19, 2012 | 18 | 2012 |
100% peer review in radiation oncology: is it feasible? E Martin-Garcia, F Celada-Álvarez, MJ Pérez-Calatayud, ... Clinical and Translational Oncology 22 (12), 2341-2349, 2020 | 17 | 2020 |
Physics Contributions A program for the independent verification of brachytherapy planning system calculations V Carmona, J Perez-Calatayud, F Lliso, J Richart, F Ballester, ... Journal of Contemporary Brachytherapy 2 (3), 129-133, 2010 | 17 | 2010 |
Monte Carlo calculation of dose rate distributions around 0.5 and 0.6 mm in diameter wires J Pérez‐Calatayud, F Lliso, V Carmona, F Ballester, C Hernández Medical Physics 26 (3), 395-401, 1999 | 15 | 1999 |
The use of nomograms in LDR-HDR prostate brachytherapy MC Pujades, C Camacho, J Perez-Calatayud, J Richart, J Gimeno, F Lliso, ... Journal of Contemporary Brachytherapy 3 (3), 121-124, 2011 | 9 | 2011 |
A Monte Carlo study of intersource effects in dome-type applicators loaded with LDR Cs-137 sources J Pérez-Calatayud, D Granero, F Ballester, F Lliso Radiotherapy and oncology 77 (2), 216-219, 2005 | 9 | 2005 |
Fetal dose measurements and shielding efficiency assessment in a custom setup of 192Ir brachytherapy for a pregnant woman with breast cancer C Candela-Juan, J Gimeno-Olmos, MC Pujades, MJ Rivard, V Carmona, ... Physica Medica 31 (3), 286-292, 2015 | 8 | 2015 |
A Monte Carlo study of dose rate distribution around the specially asymmetric CSM3-a 137Cs source J Pérez-Calatayud, F Lliso, F Ballester, MA Serrano, JL Lluch, Y Limami, ... Physics in Medicine & Biology 46 (7), N169, 2001 | 8 | 2001 |
Induced attenuation in Ce3+ and Nd3+ doped fibers irradiated with electron beams under low dose regime JL Cruz, F Lliso-Valverde, MV Andrés, J Pérez-Calatayud Optics communications 252 (4-6), 286-291, 2005 | 7 | 2005 |
Virtual simulation in radiation therapy planning. Report of five-year experience. I Petschen, J Pérez-Calatayud, A Tormo, F Lliso, M Badal, V Carmona, ... Clinical & Translational Oncology 2 (4), 2000 | 7 | 2000 |