Computation of peak lightning-induced voltages due to the typical first and subsequent strokes considering high ground resistivity MEM Rizk, F Mahmood, M Lehtonen, EA Badran, MH Abdel-Rahman IEEE Transactions on Power Delivery 32 (4), 1861-1871, 2016 | 29 | 2016 |
Investigation of lightning electromagnetic fields on underground cables in wind farms MEM Rizk, F Mahmood, M Lehtonen, EA Badran, MH Abdel-Rahman IEEE Transactions on Electromagnetic Compatibility 58 (1), 143-152, 2015 | 27 | 2015 |
Effects of environmental factors on partial discharge activity and estimation of insulation lifetime in electrical machines W Hassan, GA Hussain, F Mahmood, S Amin, M Lehtonen IEEE Access 8, 108491 - 108502, 2020 | 24 | 2020 |
Risk-based insulation coordination studies for protection of medium-voltage overhead lines against lightning-induced overvoltages F Mahmood, MEM Rizk, M Lehtonen Electrical Engineering 101 (2), 311–320, 2019 | 21 | 2019 |
Influence of highly resistive ground parameters on lightning-induced overvoltages using 3-D FDTD method MEM Rizk, F Mahmood, M Lehtonen, EA Badran, MH Abdel-Rahman IEEE Transactions on Electromagnetic Compatibility 58 (3), 792-800, 2016 | 20 | 2016 |
Probabilistic risk assessment of MV insulator flashover under combined ac and lightning-induced overvoltages F Mahmood, NA Sabiha, M Lehtonen IEEE Transactions on Power Delivery 30 (4), 1880-1888, 2015 | 20 | 2015 |
Risk assessment of low voltage motors based on PD measurements and insulation diagnostics W Hassan, F Mahmood, GA Hussain, S Amin Measurement 176, 109151, 2021 | 19 | 2021 |
Review on partial discharge diagnostic techniques for high voltage equipment in power systems GA Hussain, W Hassan, F Mahmood, M Shafiq, H Rehman, JA Kay IEEE Access 11, 51382-51394, 2023 | 18 | 2023 |
Evaluation by implementation of distribution system planning for energy loss reduction SA Qureshi, F Mahmood Pakistan Journal of Engineering and Applied Sciences, 2009 | 18 | 2009 |
Failure risk assessment of surge arrester using paralleled spark gap N A. Sabiha, F Mahmood, A M. Abd-Elhady IEEE Access 8, 217098 - 217107, 2020 | 16 | 2020 |
Influence of voltage harmonics on partial discharge diagnostics in electric motors fed by variable-frequency drives W Hassan, F Mahmood, A Andreotti, M Pagano, F Ahmad IEEE Transactions on Industrial Electronics 69 (10), 10605-10614, 2021 | 15 | 2021 |
Performance evaluation of noise reduction method during on-line monitoring of MV switchgear for PD measurements by non-intrusive sensors GA Hussain, M Shafiq, L Kumpulainen, F Mahmood, M Lehtonen International Journal of Electrical Power & Energy Systems 64, 596-607, 2015 | 15 | 2015 |
An accurate approach for the evaluation of the performance of overhead distribution lines due to indirect lightning A Andreotti, R Araneo, F Mahmood, A Pierno Electric Power Systems Research 186, 106411, 2020 | 14 | 2020 |
Induced voltages on overhead line by return strokes to grounded wind tower considering horizontally stratified ground MEM Rizk, F Mahmood, M Lehtonen, EA Badran, MH Abdel-Rahman IEEE Transactions on Electromagnetic Compatibility 58 (6), 1728-1738, 2016 | 14 | 2016 |
Application of wavelet multi-resolution analysis & perceptron neural networks for classification of transients on transmission line F Mahmood, SA Qureshi, M Kamran 2008 Australasian Universities Power Engineering Conference, 1-5, 2008 | 14 | 2008 |
Feature extraction of partial discharges during multiple simultaneous defects in low voltage electric machines W Hassan, F Mahmood, GA Hussain, S Amin, J A. Kay IEEE Transactions on Instrumentation and Measurement 70, 1-10, 2021 | 13 | 2021 |
An analytical approach to assess the influence of shield wires in improving the lightning performance due to indirect strokes A Andreotti, R Araneo, F Mahmood, A Piantini, M Rubinstein IEEE Transactions on Power Delivery 36 (3), 1491-1498, 2020 | 12 | 2020 |
Optimum operation of low voltage variable‐frequency drives to improve the performance of heating, ventilation, and air conditioning chiller system W Hassan, F Mahmood, M Akmal, M Nasir International Transactions on Electrical Energy Systems 30, e12481, 2020 | 12 | 2020 |
Effect of combined AC and lightning-induced overvoltages on the risk of MV insulator flashovers above lossy ground F Mahmood, NA Sabiha, M Lehtonen Electric Power Systems Research 127, 101-108, 2015 | 12 | 2015 |
Application of passive filters to mitigate power quality problems caused by induction furnaces MR Arif, F Mahmood, M Hashmi, S Hänninen 2012 IEEE International Conference on Condition Monitoring and Diagnosis …, 2012 | 12 | 2012 |