SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes G Poludniowski, G Landry, F Deblois, PM Evans, F Verhaegen Physics in Medicine & Biology 54 (19), N433, 2009 | 865 | 2009 |
Dual energy CT in radiotherapy: current applications and future outlook W Van Elmpt, G Landry, M Das, F Verhaegen Radiotherapy and Oncology 119 (1), 137-144, 2016 | 183 | 2016 |
Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation G Landry, R Nijhuis, G Dedes, J Handrack, C Thieke, G Janssens, ... Medical physics 42 (3), 1354-1366, 2015 | 152 | 2015 |
Deriving effective atomic numbers from DECT based on a parameterization of the ratio of high and low linear attenuation coefficients G Landry, J Seco, M Gaudreault, F Verhaegen Physics in Medicine & Biology 58 (19), 6851, 2013 | 146 | 2013 |
ScatterNet: a convolutional neural network for cone‐beam CT intensity correction DC Hansen, G Landry, F Kamp, M Li, C Belka, K Parodi, C Kurz Medical physics 45 (11), 4916-4926, 2018 | 136 | 2018 |
Dual‐energy CT quantitative imaging: a comparison study between twin‐beam and dual‐source CT scanners IP Almeida, LEJR Schyns, MC Öllers, W van Elmpt, K Parodi, G Landry, ... Medical physics 44 (1), 171-179, 2017 | 136 | 2017 |
Medical physics challenges in clinical MR-guided radiotherapy C Kurz, G Buizza, G Landry, F Kamp, M Rabe, C Paganelli, G Baroni, ... Radiation Oncology 15, 1-16, 2020 | 133 | 2020 |
CBCT correction using a cycle-consistent generative adversarial network and unpaired training to enable photon and proton dose calculation C Kurz, M Maspero, MHF Savenije, G Landry, F Kamp, M Pinto, M Li, ... Physics in Medicine & Biology 64 (22), 225004, 2019 | 120 | 2019 |
Investigating deformable image registration and scatter correction for CBCT‐based dose calculation in adaptive IMPT C Kurz, F Kamp, YK Park, C Zöllner, S Rit, D Hansen, M Podesta, ... Medical physics 43 (10), 5635-5646, 2016 | 118 | 2016 |
Comparison of proton therapy treatment planning for head tumors with a pencil beam algorithm on dual and single energy CT images N Hudobivnik, F Schwarz, T Johnson, L Agolli, G Dedes, T Tessonnier, ... Medical physics 43 (1), 495-504, 2016 | 115 | 2016 |
Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition G Landry, B Reniers, L Murrer, L Lutgens, E Bloemen‐Van Gurp, ... Medical physics 37 (10), 5188-5198, 2010 | 114 | 2010 |
Comparing cone-beam CT intensity correction methods for dose recalculation in adaptive intensity-modulated photon and proton therapy for head and neck cancer C Kurz, G Dedes, A Resch, M Reiner, U Ganswindt, R Nijhuis, C Thieke, ... Acta oncologica 54 (9), 1651-1657, 2015 | 112 | 2015 |
Current state and future applications of radiological image guidance for particle therapy G Landry, C Hua Medical Physics 45 (11), e1086-e1095, 2018 | 110 | 2018 |
Extracting atomic numbers and electron densities from a dual source dual energy CT scanner: experiments and a simulation model G Landry, B Reniers, PV Granton, B van Rooijen, L Beaulieu, ... Radiotherapy and Oncology 100 (3), 375-379, 2011 | 109 | 2011 |
High contrast optical switching in vanadium dioxide thin films T Ben-Messaoud, G Landry, JP Gariepy, B Ramamoorthy, PV Ashrit, ... Optics Communications 281 (24), 6024-6027, 2008 | 92 | 2008 |
Comparing Unet training with three different datasets to correct CBCT images for prostate radiotherapy dose calculations G Landry, D Hansen, F Kamp, M Li, B Hoyle, J Weller, K Parodi, C Belka, ... Physics in Medicine & Biology 64 (3), 035011, 2019 | 88 | 2019 |
ALGEBRA: ALgorithm for the heterogeneous dosimetry based on GEANT4 for BRAchytherapy H Afsharpour, G Landry, M D’Amours, S Enger, B Reniers, E Poon, ... Physics in Medicine & Biology 57 (11), 3273, 2012 | 86 | 2012 |
Experimental comparison of proton CT and dual energy x-ray CT for relative stopping power estimation in proton therapy G Dedes, J Dickmann, K Niepel, P Wesp, RP Johnson, M Pankuch, ... Physics in Medicine & Biology 64 (16), 165002, 2019 | 81 | 2019 |
Simulation study on potential accuracy gains from dual energy CT tissue segmentation for low-energy brachytherapy Monte Carlo dose calculations G Landry, PV Granton, B Reniers, MC Öllers, L Beaulieu, JE Wildberger, ... Physics in Medicine & Biology 56 (19), 6257, 2011 | 78 | 2011 |
A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark DC Hansen, J Seco, TS Sørensen, JBB Petersen, JE Wildberger, ... Acta oncologica 54 (9), 1638-1642, 2015 | 76 | 2015 |