PCM integrated to external building walls: An optimization study on maximum activation of latent heat M Arıcı, F Bilgin, S Nižetić, H Karabay Applied Thermal Engineering 165, 114560, 2020 | 274 | 2020 |
Melting of nanoparticle-enhanced paraffin wax in a rectangular enclosure with partially active walls M Arıcı, E Tütüncü, M Kan, H Karabay International Journal of Heat and Mass Transfer 104, 7-17, 2017 | 156 | 2017 |
Flow and heat transfer in double, triple and quadruple pane windows M Arıcı, H Karabay, M Kan Energy and Buildings 86, 394-402, 2015 | 152 | 2015 |
Comparison of a theoretical and experimental thermal conductivity model on the heat transfer performance of Al2O3-SiO2/water hybrid-nanofluid Ç Yıldız, M Arıcı, H Karabay International Journal of Heat and Mass Transfer 140, 598-605, 2019 | 133 | 2019 |
Thermal performance based optimization of an office wall containing PCM under intermittent cooling operation E Tunçbilek, M Arıcı, M Krajčík, S Nižetić, H Karabay Applied Thermal Engineering 179, 115750, 2020 | 121 | 2020 |
Determination of optimum thickness of double-glazed windows for the climatic regions of Turkey M Arıcı, H Karabay Energy and Buildings 42 (10), 1773-1778, 2010 | 112 | 2010 |
Predictions of effect of swirl on flow and heat transfer in a rotating cavity H Karabay, M Wilson, JM Owen International Journal of Heat and Fluid Flow 22 (2), 143-155, 2001 | 107 | 2001 |
A numerical investigation of fluid flow and heat transfer inside a room for floor heating and wall heating systems H Karabay, M Arıcı, M Sandık Energy and Buildings 67, 471-478, 2013 | 103 | 2013 |
Flow in a “cover-plate” preswirl rotor–stator system H Karabay, JX Chen, R Pilbrow, M Wilson, JM Owen | 81 | 1999 |
Multiple pane window applications in various climatic regions of Turkey H Karabay, M Arıcı Energy and buildings 45, 67-71, 2012 | 80 | 2012 |
Experimental investigation of inclined liquid water jet flow onto vertically located superhydrophobic surfaces A Kibar, H Karabay, KS Yiğit, IO Ucar, HY Erbil Experiments in fluids 49, 1135-1145, 2010 | 74 | 2010 |
Heat transfer in a “cover-plate” preswirl rotating-disk system R Pilbrow, H Karabay, M Wilson, JM Owen | 71 | 1999 |
A review on thermal comfort, indoor air quality and energy consumption in temples A Yüksel, M Arıcı, M Krajčík, M Civan, H Karabay Journal of Building Engineering 35, 102013, 2021 | 69 | 2021 |
Thermo-economic optimization of hot water piping systems: A comparison study İT Öztürk, H Karabay, E Bilgen Energy 31 (12), 2094-2107, 2006 | 60 | 2006 |
Performance of pre-swirl rotating-disc systems H Karabay, R Pilbrow, M Wilson, JM Owen J. Eng. Gas Turbines Power 122 (3), 442-450, 2000 | 53 | 2000 |
Energy saving and CO2 reduction potential of external building walls containing two layers of phase change material M Arıcı, F Bilgin, M Krajčík, S Nižetić, H Karabay Energy 252, 124010, 2022 | 48 | 2022 |
Approximate solutions for flow and heat transfer in pre-swirl rotating-disc systems H Karabay, M Wilson, JM Owen Turbo Expo: Power for Land, Sea, and Air 78521, V003T01A074, 2001 | 39 | 2001 |
Energy consumption, thermal comfort, and indoor air quality in mosques: Impact of Covid-19 measures A Yüksel, M Arıcı, M Krajčík, M Civan, H Karabay Journal of Cleaner Production 354, 131726, 2022 | 30 | 2022 |
Is the thermal transmittance of air-filled inclined multi-glazing windows similar to that of vertical ones? M Arıcı, M Tükel, Ç Yıldız, D Li, H Karabay Energy and Buildings 229, 110515, 2020 | 29 | 2020 |
Experimental investigation of thermal comfort and CO2concentration in mosques: A case study in warm temperate climate of Yalova, Turkey A Yüksel, M Arıcı, M Krajčík, H Karabay Sustainable Cities and Society 52, 101809, 2020 | 29 | 2020 |