Active colonoscopy training model and method of using the same JH Choi US Patent 9,990,862, 2018 | 69 | 2018 |
Development of a segmental bioelectrical impedance spectroscopy device for body composition measurement T Cannon, JH Choi Sensors 19 (22), 4825, 2019 | 23 | 2019 |
Detection of endoscopic looping during colonoscopy procedure by using embedded bending sensors M Bruce, JH Choi Medical Devices: Evidence and Research, 171-191, 2018 | 11 | 2018 |
Preliminary development of the active colonoscopy training model J Choi, K Ravindra, R Robert, D Drozek Medical Devices: Evidence and Research, 59-70, 2011 | 10 | 2011 |
Hoffmann reflex measured from lateral gastrocnemius is more reliable than from soleus among elderly with peripheral neuropathy Q Song, M Sun, K Lewis, JH Choi, B Manor, L Li Frontiers in aging neuroscience 14, 800698, 2022 | 7 | 2022 |
Method and device for evaluating a colonoscopy procedure JH Choi US Patent App. 14/759,236, 2015 | 6 | 2015 |
Development of a colonoscopy add-on device for improvement of the intubation process JD Litten, JH Choi, D Drozek Medical Devices: Evidence and Research, 197-208, 2011 | 6 | 2011 |
Evaluation of Active Colonoscopy Training Model R Kale, D Koonce, D Drozek, JH Choi J. Med. Devices. 7 (4), 041008-041008-7., 2013 | 5 | 2013 |
Development of an Automatic Adjustable Colonoscope JD Litten, JH Choi, D Drozek | 4 | 2011 |
Preliminary Element Design and Analysis of a Smart Endoscope J Choi, RH Sturges Flexible Automation & Intelligent Manufacturing, 2004 | 4 | 2004 |
The Reduced Adaptability of H-Reflex Parameters to Postural Change With Deficiency of Foot Plantar Sensitivity M Sun, K Lewis, JH Choi, F Zhang, F Qu, L Li Frontiers in physiology 13, 890414, 2022 | 3 | 2022 |
A Hand-Held Device for Controlling a Mounted, Motor Driven Colonoscope CD Sheerer, D Drozek, J Choi Journal of Medical Devices 9 (3), 030924, 2015 | 3 | 2015 |
Medical Equipment to Make Colonoscopy Procedures Safer for Physicians: Control Head Holder and Splatter Shield R Shanbhag, IF Kadhim, B Clark, N Kumar Mahato, D Drozek, JH Choi Journal of Medical Devices 8 (3), 030953, 2014 | 3 | 2014 |
Development and Evaluation of the Innovative Smartphone Interface Bioelectrical Impedance Analyzer BH Choi, H Joon Kang, H Gil Cho, JH Choi Journal of Medical Devices 7 (2), 020935, 2013 | 3 | 2013 |
Detection of looping during colonoscopy using bending sensors JH Choi, D Drozek The Open Medical Devices Journal 5 (1), 2013 | 3 | 2013 |
Method for Detecting Ablation Damage Using Sensor Integration of Hot Biopsy Forceps R Robert, L Chen, R Shanbhag, D Drozek, JH Choi Journal of Medical Devices 7 (3), 030948, 2013 | 2 | 2013 |
Evaluation of Active Colonoscopy Training Model (ACTM) R V. Kale, JH Choi, D Drozek Journal of Medical Devices 6 (1), 017555, 2012 | 2 | 2012 |
The effect of loss of foot sole sensitivity on H-reflex of triceps surae muscles and functional gait F Zhang, M Sun, F Qu, K Lewis, JH Choi, Q Song, L Li Frontiers in Physiology 13, 1036122, 2023 | 1 | 2023 |
The Calibration of a Bioelectrical Impedance Spectroscopy Device JH Choi Frontiers in Biomedical Devices 84812, V001T12A008, 2021 | 1 | 2021 |
Extension Mechanism of a Flexible End for Colonoscopy I Kadhim, J Choi Medical Devices: Evidence and Research, 245-258, 2020 | 1 | 2020 |