Optical biosensor for pharmaceuticals, antibiotics, hormones, endocrine disrupting chemicals and pesticides in water: Assay optimization process for estrone as example J Tschmelak, G Proll, G Gauglitz Talanta 65 (2), 313-323, 2005 | 126 | 2005 |
Automated Water Analyser Computer Supported System (AWACSS): Part II: Intelligent, remote-controlled, cost-effective, on-line, water-monitoring measurement system J Tschmelak, G Proll, J Riedt, J Kaiser, P Kraemmer, L Bárzaga, ... Biosensors and Bioelectronics 20 (8), 1509-1519, 2005 | 116 | 2005 |
Automated Water Analyser Computer Supported System (AWACSS) Part I: Project objectives, basic technology, immunoassay development, software design and networking J Tschmelak, G Proll, J Riedt, J Kaiser, P Kraemmer, L Bárzaga, ... Biosensors and Bioelectronics 20 (8), 1499-1508, 2005 | 116 | 2005 |
Verification of performance with the automated direct optical TIRF immunosensor (River Analyser) in single and multi-analyte assays with real water samples J Tschmelak, G Proll, G Gauglitz Biosensors and Bioelectronics 20 (4), 743-752, 2004 | 86 | 2004 |
Total internal reflectance fluorescence (TIRF) biosensor for environmental monitoring of testosterone with commercially available immunochemistry: Antibody characterization … J Tschmelak, M Kumpf, N Käppel, G Proll, G Gauglitz Talanta 69 (2), 343-350, 2006 | 83 | 2006 |
Potential of label-free detection in high-content-screening applications G Proll, L Steinle, F Pröll, M Kumpf, B Moehrle, M Mehlmann, G Gauglitz Journal of Chromatography A 1161 (1-2), 2-8, 2007 | 76 | 2007 |
Integrated optical fluorescence multisensor for water pollution P Hua, JP Hole, JS Wilkinson, G Proll, J Tschmelak, G Gauglitz, ... Optics Express 13 (4), 1124-1130, 2005 | 75 | 2005 |
Strategies for label-free optical detection G Gauglitz, G Proll Biosensing for the 21st Century, 395-432, 2008 | 72 | 2008 |
Size does matter! Label-free detection of small molecule–protein interaction P Fechner, O Bleher, M Ewald, K Freudenberger, D Furin, U Hilbig, ... Analytical and bioanalytical chemistry 406, 4033-4051, 2014 | 49 | 2014 |
Sub-nanogram per litre detection of the emerging contaminant progesterone with a fully automated immunosensor based on evanescent field techniques J Tschmelak, G Proll, G Gauglitz Analytica chimica acta 519 (2), 143-146, 2004 | 48 | 2004 |
Immunosensor for estrone with an equal limit of detection as common analytical methods J Tschmelak, G Proll, G Gauglitz Analytical and bioanalytical chemistry 378, 744-745, 2004 | 42 | 2004 |
Comparative studies on two potential methods for the biotechnological production of sponge biomass M Nickel, S Leininger, G Proll, F Brümmer Journal of biotechnology 92 (2), 169-178, 2001 | 42 | 2001 |
Direct optical detection in fragment-based screening F Pröll, P Fechner, G Proll Analytical and bioanalytical chemistry 393, 1557-1562, 2009 | 40 | 2009 |
Biosensor for seven sulphonamides in drinking, ground, and surface water with difficult matrices J Tschmelak, M Kumpf, G Proll, G Gauglitz Analytical letters 37 (8), 1701-1718, 2004 | 39 | 2004 |
Development of a new parallelized, optical biosensor platform for label-free detection of autoimmunity-related antibodies O Bleher, A Schindler, MX Yin, AB Holmes, PB Luppa, G Gauglitz, G Proll Analytical and bioanalytical chemistry 406, 3305-3314, 2014 | 37 | 2014 |
Monitoring an antibody affinity chromatography with a label-free optical biosensor technique G Proll, M Kumpf, M Mehlmann, J Tschmelak, H Griffith, R Abuknesha, ... Journal of immunological methods 292 (1-2), 35-42, 2004 | 34 | 2004 |
Ultra-sensitive fully automated immunoassay for detection of propanil in aqueous samples: steps of progress toward sub-nanogram per liter detection J Tschmelak, G Proll, G Gauglitz Analytical and bioanalytical chemistry 379, 1004-1012, 2004 | 34 | 2004 |
An advanced biosensor for the prediction of estrogenic effects of endocrine-disrupting chemicals on the estrogen receptor alpha P Fechner, F Pröll, M Carlquist, G Proll Analytical and Bioanalytical Chemistry 393, 1579-1585, 2009 | 32 | 2009 |
Reflectometric interference spectroscopy G Proll, G Markovic, L Steinle, G Gauglitz Biosensors and Biodetection, 167-178, 2009 | 32 | 2009 |
A robust sensor platform for label-free detection of anti-Salmonella antibodies using undiluted animal sera M Ewald, AF Le Blanc, G Gauglitz, G Proll Analytical and bioanalytical chemistry 405, 6461-6469, 2013 | 29 | 2013 |