关注
Rajesh Ghosh
Rajesh Ghosh
Associate Professor, School of Mechanical and Materials Engineering, IIT Mandi
在 iitmandi.ac.in 的电子邮件经过验证 - 首页
标题
引用次数
引用次数
年份
Finite element analysis of a hemi-pelvis: the effect of inclusion of cartilage layer on acetabular stresses and strain
R Ghosh, B Pal, D Ghosh, S Gupta
Computer methods in biomechanics and biomedical engineering 18 (7), 697-710, 2015
812015
Experimental validation of finite element models of intact and implanted composite hemipelvises using digital image correlation
R Ghosh, S Gupta, A Dickinson, M Browne
Journal of Biomechanical Engineering 134 (8), 081003, 2012
802012
Bone remodelling around cementless composite acetabular components: the effects of implant geometry and implant–bone interfacial conditions
R Ghosh, S Gupta
Journal of the Mechanical Behavior of Biomedical materials 32, 257-269, 2014
632014
Bone remodelling around uncemented metallic and ceramic acetabular components
R Ghosh, K Mukherjee, S Gupta
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2013
482013
A numerical study on stress distribution across the ankle joint: Effects of material distribution of bone, muscle force and ligaments
S Mondal, R Ghosh
Journal of orthopaedics 14 (3), 329-335, 2017
402017
Effects of implant orientation and implant material on tibia bone strain, implant–bone micromotion, contact pressure, and wear depth due to total ankle replacement
S Mondal, R Ghosh
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2019
362019
Experimental validation of numerically predicted strain and micromotion in intact and implanted composite hemi-pelvises
R Ghosh, S Gupta, A Dickinson, M Browne
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2013
362013
Bone remodelling around the tibia due to total ankle replacement: effects of implant material and implant–bone interfacial conditions
S Mondal, R Ghosh
Computer Methods in Biomechanics and Biomedical Engineering 22 (16), 1247-1257, 2019
232019
The effects of implant orientations and implant–bone interfacial conditions on potential causes of failure of tibial component due to total ankle replacement
S Mondal, R Ghosh
Journal of Medical and Biological Engineering 39, 541-551, 2019
232019
Experimental and numerical comparisons between finite element method, element-free Galerkin method, and extended finite element method predicted stress intensity factor and …
A Kumar, P Shitole, R Ghosh, R Kumar, A Gupta
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2019
192019
A review on experimental and numerical investigations of cortical bone fracture
A Kumar, R Ghosh
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2022
182022
Biomechanical analysis of three popular tibial designs for TAR with different implant-bone interfacial conditions and bone qualities: A finite element study
Jyoti, S Mondal, R Ghosh
Medical Engineering & Physics 104, 103812, 2022
172022
Experimental and finite element investigation of total ankle replacement: A review of literature and recommendations
S Mondal, R Ghosh
Journal of Orthopaedics 18, 41-49, 2020
172020
Assessment of failure of cemented polyethylene acetabular component due to bone remodeling: A finite element study
R Ghosh
Journal of Orthopaedics 13 (3), 140-147, 2016
172016
Effects of interfacial crack and implant material on mixed‐mode stress intensity factor and prediction of interface failure of cemented acetabular cup
A Kumar, R Ghosh, R Kumar
Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2019
152019
Fracture toughness of acrylic PMMA bone cement: a mini-review
A Kumar, R Ghosh
Indian Journal of Orthopaedics 55 (5), 1208-1214, 2021
132021
Towards the optimal design of an uncemented acetabular component using genetic algorithms
R Ghosh, DK Pratihar, S Gupta
Engineering Optimization 47 (12), 1587 - 1601, 2015
132015
Stability analysis of a flexible spinning and precessing rotor with non-symmetric shaft
R Ghosh, A Saha, A Nandi, S Neogy
Journal of Vibration and Control 16 (1), 107-125, 2010
122010
Influence of cancellous bone material and dead zone on stress-strain, bone stimulus and bone remodelling around the tibia for total ankle replacement
S Mondal, R Ghosh
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2021
102021
Influence of interface crack and non-uniform cement thickness on mixed-mode stress intensity factor and prediction of interface failure of cemented acetabular cup
A Kumar, D Sanjay, S Mondal, R Ghosh, R Kumar
Theoretical and Applied Fracture Mechanics 107, 102524, 2020
92020
系统目前无法执行此操作,请稍后再试。
文章 1–20