High and Low Fluences of α-Particles Induce a G1 Checkpoint in Human Diploid Fibroblasts EI Azzam, SM De Toledo, AJ Waker, JB Little Cancer research 60 (10), 2623-2631, 2000 | 143 | 2000 |
Principals of experimental microdosimetry AJ Waker Radiation protection dosimetry 61 (4), 297-308, 1995 | 114 | 1995 |
Microdosimetry: experimental methods and applications L Lindborg, A Waker CRC Press, 2017 | 76 | 2017 |
Design of tissue-equivalent proportional counters P Kliauga, AJ Waker, J Barthe Radiation protection dosimetry 61 (4), 309-322, 1995 | 54 | 1995 |
Intercomparison of dose equivalent meters based on microdosimetric techniques: detailed analysis and conclusions HG Menzel, L Lindborg, T Schmitz, H Schuhmacher, AJ Waker Radiation Protection Dosimetry 29 (1-2), 55-68, 1989 | 49 | 1989 |
Experimental uncertainties in microdosimetric measurements and an examination of the performance of three commercially produced proportional counters AJ Waker Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 1985 | 48 | 1985 |
An accelerator based system for in vivo neutron activation analysis measurements of manganese in human hand bones ML Arnold, FE McNeill, IM Stronach, A Pejovic‐Milic, DR Chettle, A Waker Medical physics 29 (11), 2718-2724, 2002 | 47 | 2002 |
Modelling DNA damage induced by different energy photons and tritium beta-particles VV Moiseenko International journal of radiation biology 74 (5), 533-550, 1998 | 45 | 1998 |
Miniature tissue‐equivalent proportional counters for BNCT and BNCEFNT dosimetry J Burmeister, C Kota, RL Maughan, AJ Waker Medical physics 28 (9), 1911-1925, 2001 | 36 | 2001 |
Development of a thick gas electron multiplier for microdosimetry GM Orchard, K Chin, WV Prestwich, AJ Waker, SH Byun Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2011 | 31 | 2011 |
Investigating the TEPC radiation quality factor response for low energy accelerator based clinical applications Aslam, W V. Prestwich, F E. McNeill, A J. Waker Radiation protection dosimetry 103 (4), 311-322, 2003 | 31 | 2003 |
Simulation and first test of a microdosimetric detector based on a thick gas electron multiplier SH Byun, GM Spirou, A Hanu, WV Prestwich, AJ Waker IEEE Transactions on Nuclear Science 56 (3), 1108-1113, 2009 | 30 | 2009 |
TEPC performance in the CANDU workplace AJ Waker, K Szornel, J Nunes Radiation protection dosimetry 70 (1-4), 197-202, 1997 | 29 | 1997 |
Design, construction and use of tissue equivalent proportional counters EURADOS report T Schmitz, AJ Waker, P Kliauga, H Zoetelief Radiation protection dosimetry 61 (4), 1995 | 27 | 1995 |
Calculation of radiation-induced DNA damage from photons and tritium beta-particles: Part II: Tritium RBE and damage complexity VV Moiseenko, AJ Waker, RN Hamm, WV Prestwich Radiation and Environmental Biophysics 40, 33-38, 2001 | 25 | 2001 |
Development of an accelerator based determination of aluminum burden in peripheral bone by neutron activation analysis A Pejović-Milić, F E McNeill, WV Prestwich, AJ Waker, D R Chettle Toronto Metropolitan University, 1998 | 25 | 1998 |
Measurement of the restricted LET of photon sources (5 keV-1.2 MeV) by the recombination method: theory and practice G Makrigiorgos, AJ Waker Physics in Medicine & Biology 31 (5), 543, 1986 | 23 | 1986 |
Neutron microdosimetric response of a gas electron multiplier J Dubeau, AJ Waker Radiation protection dosimetry 128 (4), 413-420, 2008 | 21 | 2008 |
The cellular environment in computer simulations of radiation-induced damage to DNA VV Moiseenko, RN Hamm, AJ Waker, WV Prestwich Radiation and environmental biophysics 37, 167-172, 1998 | 20 | 1998 |
Design of a multi-element TEPC for neutron monitoring AJ Waker, Aslam, J Lori Radiation protection dosimetry 143 (2-4), 463-466, 2011 | 19 | 2011 |