Behavior of framed modular building system with double skin steel panels SG Hong, BH Cho, KS Chung, J Moon Journal of Constructional Steel Research 67 (6), 936-946, 2011 | 108 | 2011 |
Structural performance of a new blind-bolted frame modular beam-column connection under lateral loading BH Cho, JS Lee, H Kim, DJ Kim Applied Sciences 9 (9), 1929, 2019 | 52 | 2019 |
Dynamic parameter identification of secondary mass dampers based on full‐scale tests BH Cho, JS Jo, SJ Joo, H Kim Computer‐Aided Civil and Infrastructure Engineering 27 (3), 218-230, 2012 | 38 | 2012 |
Extended technology acceptance model to explain the mechanism of modular construction adoption J Shin, S Moon, B Cho, S Hwang, B Choi Journal of Cleaner Production 342, 130963, 2022 | 35 | 2022 |
Performance test of a tuned liquid mass damper for reducing bidirectional responses of building structures JS Heo, SK Lee, E Park, SH Lee, KW Min, H Kim, J Jo, BH Cho The Structural Design of Tall and Special Buildings 18 (7), 789-805, 2009 | 30 | 2009 |
Finite element model updating of multi-span greenhouses based on ambient vibration measurements T Ha, J Kim, BH Cho, DJ Kim, JE Jung, SH Shin, H Kim Biosystems Engineering 161, 145-156, 2017 | 28 | 2017 |
Development of an Efficient Steel Beam Section for Modular Construction Based on Six‐Sigma TH Ha, BH Cho, H Kim, DJ Kim Advances in Materials Science and Engineering 2016 (1), 9687078, 2016 | 18 | 2016 |
Development of an exportable modular building system by integrating quality function deployment and TRIZ method S Oh, B Cho, DJ Kim Journal of Asian Architecture and Building Engineering 16 (3), 535-542, 2017 | 15 | 2017 |
Earthquake resistance of modular building units using load-bearing steel stud panels TH Ha, BH Cho, TH Kim, DY Lee, TS Eom Journal of Korean Society of Steel Construction 25 (5), 519-530, 2013 | 15 | 2013 |
Cyclic loading tests on framed stud walls with strap braces and steel sheathing TS Eom, TH Ha, BH Cho, TH Kim Journal of Structural Engineering 141 (7), 04014173, 2015 | 14 | 2015 |
Integrated management software for factory production of modular buildings SH Nam, DY Lee, BH Cho, KR Kim Advances in Civil Engineering 2019 (1), 7693459, 2019 | 9 | 2019 |
Factory Production Management of Modular Units Using MFD 2019 DY Lee, SH Nam, JS Lee, DI Jung, K Kim, BH Cho Journal of the Architectural Institute of Korea Structure & Construction 35 …, 2019 | 7 | 2019 |
Performance evaluation of rigid braced indirect suspended ceiling with steel panels JS Lee, DI Jung, DY Lee, BH Cho Applied Sciences 11 (5), 1986, 2021 | 6 | 2021 |
Effective assessment of inelastic torsional deformation of plan-asymmetric shear wall systems T Ha, SG Hong, BH Cho, DJ Kim Applied Sciences 9 (14), 2814, 2019 | 6 | 2019 |
An experimental study on fire resistance of medical modular block 김형준, 조봉호, 이재승, 김흥열, 권기혁 Steel and Composite Structures, An International Journal 15 (1), 103-130, 2013 | 6 | 2013 |
A Tuned Liquid Mass Damper (TLMD) for Controlling Bi-directional Responses of a Building Structure JS Heo, EC Park, SH Lee, SK Lee, HJ Kim, BH Cho, JS Jo, DY Kim, ... Transactions of the Korean Society for Noise and Vibration Engineering 18 (3 …, 2008 | 6 | 2008 |
Experimental study on the cyclic behavior of integrated panels for cold-formed steel shear wall system DY Lee, BH Cho, DI Jung, JS Lee, KW Lee Applied Sciences 10 (5), 1649, 2020 | 5 | 2020 |
Performance evaluation of perimeter reinforced t-bar type suspended ceiling with steel-panel using shaking table test JS Lee, DI Jung, DY Lee, BH Cho Journal of the Architectural Institute of Korea 36 (10), 167-175, 2020 | 5 | 2020 |
Shaking-Table evaluation of seismic performance of suspended steel-panel ceiling J Lee, S In, D Jung, S Lee, B Cho 4th International Workshop on the Seismic Performance of Non-Structural …, 2019 | 5 | 2019 |
Modal parameters estimation of building structures from vibration test data using observability measurement JS Hwang, H Kim, BH Cho Shock and Vibration 2015 (1), 627852, 2015 | 5 | 2015 |