Self-decoupled radiofrequency coils for magnetic resonance imaging X Yan, JC Gore, WA Grissom Nature communications 9 (1), 3481, 2018 | 105 | 2018 |
7T transmit/receive arrays using ICE decoupling for human head MR imaging X Yan, X Zhang, B Feng, CX Ma, L Wei, R Xue IEEE transactions on medical imaging 33 (9), 1781-1787, 2014 | 60 | 2014 |
A monopole/loop dual-tuned RF coil for ultrahigh field MRI X Yan, R Xue, X Zhang Quantitative imaging in medicine and surgery 4 (4), 225, 2014 | 52 | 2014 |
Design and test of magnetic wall decoupling for dipole transmit/receive array for MR imaging at the ultrahigh field of 7T X Yan, X Zhang, L Wei, R Xue Applied magnetic resonance 46, 59-66, 2015 | 48 | 2015 |
Magnetic wall decoupling method for monopole coil array in ultrahigh field MRI: a feasibility test X Yan, X Zhang, L Wei, R Xue Quantitative imaging in Medicine and Surgery 4 (2), 79, 2014 | 46 | 2014 |
Hybrid monopole/loop coil array for human head MR imaging at 7 T X Yan, L Wei, R Xue, X Zhang Applied magnetic resonance 46, 541-550, 2015 | 40 | 2015 |
Array‐compressed parallel transmit pulse design Z Cao, X Yan, WA Grissom Magnetic resonance in medicine 76 (4), 1158-1169, 2016 | 38 | 2016 |
Simulation verification of SNR and parallel imaging improvements by ICE-decoupled loop array in MRI X Yan, Z Cao, X Zhang Applied magnetic resonance 47 (4), 395-403, 2016 | 30 | 2016 |
Optimization of an 8-channel loop-array coil for a 7 T MRI system with the guidance of a co-simulation approach X Yan, CX Ma, L Shi, Y Zhuo, XJ Zhou, L Wei, R Xue Applied Magnetic Resonance 45, 437-449, 2014 | 30 | 2014 |
Multichannel double-row transmission line array for human MR imaging at ultrahigh fields X Yan, JO Pedersen, L Wei, X Zhang, R Xue IEEE Transactions on Biomedical Engineering 62 (6), 1652-1659, 2015 | 29 | 2015 |
Decoupling and matching network for monopole antenna arrays in ultrahigh field MRI X Yan, X Zhang Quantitative imaging in medicine and surgery 5 (4), 546, 2015 | 26 | 2015 |
Closely spaced double-row microstrip RF arrays for parallel MR imaging at ultrahigh fields X Yan, R Xue, X Zhang Applied magnetic resonance 46, 1239-1248, 2015 | 25 | 2015 |
Eight-channel monopole array using ICE decoupling for human head MR imaging at 7 T X Yan, L Wei, S Chu, R Xue, X Zhang Applied magnetic resonance 47, 527-538, 2016 | 22 | 2016 |
Experimental implementation of array‐compressed parallel transmission at 7 tesla X Yan, Z Cao, WA Grissom Magnetic resonance in medicine 75 (6), 2545-2552, 2016 | 21 | 2016 |
New resonator geometries for ICE decoupling of loop arrays X Yan, JC Gore, WA Grissom Journal of Magnetic Resonance 277, 59-67, 2017 | 20 | 2017 |
Theoretical analysis of magnetic wall decoupling method for radiative antenna arrays in ultrahigh magnetic field MRI X Yan, Z Xie, JO Pedersen, X Zhang Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering 45 (4 …, 2015 | 19 | 2015 |
Ratio‐adjustable power splitters for array‐compressed parallel transmission X Yan, Z Cao, WA Grissom Magnetic resonance in medicine 79 (4), 2422-2431, 2018 | 18 | 2018 |
Improved traveling-wave efficiency in 7 T human MRI using passive local loop and dipole arrays X Yan, X Zhang, JC Gore, WA Grissom Magnetic resonance imaging 39, 103-109, 2017 | 17 | 2017 |
Dual-tuned lattice balun for multi-nuclear MRI and MRS Y Zhu, CR Sappo, WA Grissom, JC Gore, X Yan IEEE transactions on medical imaging 41 (6), 1420-1430, 2022 | 11 | 2022 |
Sensitivity and specificity of CEST and NOE MRI in injured spinal cord in monkeys F Wang, Z Zu, TL Wu, X Yan, M Lu, PF Yang, NE Byun, JL Reed, JC Gore, ... NeuroImage: Clinical 30, 102633, 2021 | 9 | 2021 |