Biomechanical evaluation of the less invasive stabilization system, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures M Zlowodzki, S Williamson, PA Cole, LD Zardiackas, PJ Kregor Journal of orthopaedic trauma 18 (8), 494-502, 2004 | 428 | 2004 |
Surface roughness effects on the fatigue strength of additively manufactured Ti-6Al-4V J Pegues, M Roach, RS Williamson, N Shamsaei International Journal of Fatigue 116, 543-552, 2018 | 302 | 2018 |
Fatigue life estimation of additive manufactured parts in the as‐built surface condition JW Pegues, N Shamsaei, MD Roach, RS Williamson Material Design & Processing Communications 1 (3), e36, 2019 | 78 | 2019 |
Tuning anatase and rutile phase ratios and nanoscale surface features by anodization processing onto titanium substrate surfaces MD Roach, RS Williamson, IP Blakely, LM Didier Materials Science and Engineering: C 58, 213-223, 2016 | 67 | 2016 |
Comparison of the corrosion fatigue characteristics of CP Ti-Grade 4, Ti-6Al-4V ELI, Ti-6Al-7Nb, and Ti-15Mo MD Roach, RS Williamson, LD Zardiackas ASTM International, 2005 | 56 | 2005 |
Surface modifications to enhance osseointegration–Resulting material properties and biological responses KP Nobles, AV Janorkar, RS Williamson Journal of Biomedical Materials Research Part B: Applied Biomaterials 109 …, 2021 | 54 | 2021 |
Fracture fixation with two locking screws versus three non-locking screws: a biomechanical comparison in a normal and an osteoporotic bone model B Grawe, T Le, S Williamson, A Archdeacon, L Zardiackas Bone & Joint Research 1 (6), 118-124, 2012 | 40 | 2012 |
Effect of duty cycle on the crystallinity, pore size, surface roughness and corrosion resistance of the anodized surface on titanium RS Williamson, J Disegi, AV Janorkar, JA Griggs, MD Roach Surface and Coatings Technology 277, 278-288, 2015 | 38 | 2015 |
Nanopore formation on the surface oxide of commercially pure titanium grade 4 using a pulsed anodization method in sulfuric acid RS Williamson, J Disegi, JA Griggs, MD Roach Journal of Materials Science: Materials in Medicine 24, 2327-2335, 2013 | 35 | 2013 |
Photofunctionalization of anodized titanium surfaces using UVA or UVC light and its effects against Streptococcus sanguinis S Jain, RS Williamson, M Marquart, AV Janorkar, JA Griggs, MD Roach Journal of Biomedical Materials Research Part B: Applied Biomaterials 106 (6 …, 2018 | 22 | 2018 |
Surface characterization, shear strength, and bioactivity of anodized titanium prepared in mixed-acid electrolytes S Jain, RS Williamson, MD Roach Surface and Coatings Technology 325, 594-603, 2017 | 19 | 2017 |
Effect of specimen surface area size on fatigue strength of additively manufactured Ti-6Al-4V parts J Pegues, M Roach, RS Williamson, N Shamsaei University of Texas at Austin, 2017 | 17 | 2017 |
Photocatalytic activity and antibacterial efficacy of UVA-treated titanium oxides HA Johnson, RS Williamson, M Marquart, JD Bumgardner, AV Janorkar, ... Journal of biomaterials applications 35 (4-5), 500-514, 2020 | 15 | 2020 |
Volume effects on the fatigue behavior of additively manufactured Ti-6Al-4V Parts J Pegues, M Roach, RS Williamson, N Shamsaei University of Texas at Austin, 2018 | 15 | 2018 |
Osteoblast response to nanostructured and phosphorus-enhanced titanium anodization surfaces S Jain, RS Williamson, AV Janorkar, JA Griggs, MD Roach Journal of Biomaterials Applications 34 (3), 419-430, 2019 | 13 | 2019 |
Comparison of Stress Corrosion Cracking of Ti-15Mo, Ti-6Al-7Nb, Ti-6Al-4V, and CP Ti RS Williamson, MD Roach, LD Zardiackas J. Test. Eval, 2004 | 9 | 2004 |
A comparison of the stress corrosion cracking susceptibility of commercially pure titanium grade 4 in Ringer's solution and in distilled water: A fracture mechanics approach MD Roach, RS Williamson, JA Thomas, JA Griggs, LD Zardiackas Journal of Biomedical Materials Research Part B: Applied Biomaterials 102 (1 …, 2014 | 8 | 2014 |
Anodized titanium with calcium and phosphorus surface enhancements for dental and orthopedic implant applications J Nelson, S Jain, P Pal, HA Johnson, KP Nobles, AV Janorkar, ... Thin Solid Films 745, 139117, 2022 | 6 | 2022 |
Comparison of the corrosion fatigue characteristics of 23Mn-21Cr-1Mo low nickel, 22Cr-13Ni-5Mn, and 18Cr-14Ni-2.5 Mo stainless steels M Roach, R Williamson, L Zardiackas Fatigue and Fracture of Medical Metallic Materials and Devices, 2007 | 6 | 2007 |
Comparison of stress corrosion cracking and corrosion fatigue (anodized and non-anodized grade 4 CP Ti) LD Zardiackas, MD Roach, RS Williamson ASTM International, 2006 | 5 | 2006 |