Radiochromic film for medical radiation dosimetry MJ Butson, KN Peter, T Cheung, P Metcalfe Materials Science and Engineering: R: Reports 41 (3-5), 61-120, 2003 | 500 | 2003 |
Weak energy dependence of EBT gafchromic film dose response in the 50ákVp–10áMVp X-ray range MJ Butson, T Cheung, KN Peter Applied Radiation and Isotopes 64 (1), 60-62, 2006 | 255 | 2006 |
Post-irradiation colouration of Gafchromic EBT radiochromic film T Cheung, MJ Butson, KN Peter Physics in Medicine & Biology 50 (20), N281, 2005 | 249 | 2005 |
A new radiotherapy surface dose detector: the MOSFET MJ Butson, A Rozenfeld, JN Mathur, M Carolan, TPY Wong, PE Metcalfe Medical physics 23 (5), 655-658, 1996 | 198 | 1996 |
Dose response of various radiation detectors to synchrotron radiation T Kron, L Duggan, T Smith, A Rosenfeld, M Butson, G Kaplan, S Howlett, ... Physics in Medicine & Biology 43 (11), 3235, 1998 | 173 | 1998 |
Measurement of radiotherapy x‐ray skin dose on a chest wall phantom KY Quach, J Morales, MJ Butson, AB Rosenfeld, PE Metcalfe Medical physics 27 (7), 1676-1680, 2000 | 162 | 2000 |
Effects on skin dose from unwanted air gaps under bolus in photon beam radiotherapy MJ Butson, T Cheung, P Yu, P Metcalfe Radiation Measurements 32 (3), 201-204, 2000 | 146 | 2000 |
Energy response of the new EBT2 radiochromic film to x-ray radiation MJ Butson, KN Peter, T Cheung, H Alnawaf Radiation Measurements 45 (7), 836-839, 2010 | 145 | 2010 |
Scanning orientation effects on Gafchromic EBT film dosimetry MJ Butson, T Cheung, PKN Yu Australasian Physics & Engineering Sciences in Medicine 29, 281-284, 2006 | 144 | 2006 |
Absorption spectra variations of EBT radiochromic film from radiation exposure MJ Butson, T Cheung, PKN Yu Physics in Medicine & Biology 50 (13), N135, 2005 | 133 | 2005 |
Directional dependence in film dosimetry: radiographic and radiochromic film N Suchowerska, P Hoban, M Butson, A Davison, P Metcalfe Physics in Medicine & Biology 46 (5), 1391, 2001 | 128 | 2001 |
Skin dosimetry with new MOSFET detectors IS Kwan, AB Rosenfeld, ZY Qi, D Wilkinson, MLF Lerch, DL Cutajar, ... Radiation measurements 43 (2-6), 929-932, 2008 | 121 | 2008 |
Monte Carlo characterization of skin doses in 6 MV transverse field MRI‐linac systems: effect of field size, surface orientation, magnetic field strength, and exit bolus BM Oborn, PE Metcalfe, MJ Butson, AB Rosenfeld Medical Physics 37 (10), 5208-5217, 2010 | 93 | 2010 |
High resolution entry and exit Monte Carlo dose calculations from a linear accelerator 6 MV beam under the influence of transverse magnetic fields BM Oborn, PE Metcalfe, MJ Butson, AB Rosenfeld Medical Physics 36 (8), 3549-3559, 2009 | 91 | 2009 |
Dose and absorption spectra response of EBT2 Gafchromic film to high energy x-rays MJ Butson, T Cheung, PKN Yu, H Alnawaf Australasian physical & engineering sciences in medicine 32, 196-202, 2009 | 89 | 2009 |
Effects of read-out light sources and ambient light on radiochromic film MJ Butson, KN Peter, PE Metcalfe Physics in Medicine & Biology 43 (8), 2407, 1998 | 87 | 1998 |
Electron contamination modeling and skin dose in 6 MV longitudinal field MRIgRT: impact of the MRI and MRI fringe field BM Oborn, PE Metcalfe, MJ Butson, AB Rosenfeld, PJ Keall Medical physics 39 (2), 874-890, 2012 | 85 | 2012 |
Effects of temperature variation on MOSFET dosimetry T Cheung, MJ Butson, KN Peter Physics in Medicine & Biology 49 (13), N191, 2004 | 83 | 2004 |
TLD extrapolation for skin dose determination in vivo T Kron, M Butson, F Hunt, J Denham Radiotherapy and oncology 41 (2), 119-123, 1996 | 78 | 1996 |
Measurement of high energy x‐ray beam penumbra with Gafchromic™ EBT radiochromic film T Cheung, MJ Butson, PKN Yu Medical physics 33 (8), 2912-2914, 2006 | 76 | 2006 |