A mathematical reason for FEV1/FVC dependence on age T Gólczewski, W Lubiński, A Chciałowski Respiratory research 13, 1-7, 2012 | 39 | 2012 |
Physiologically interpretable prediction equations for spirometric indexes W Lubiński, T Gólczewski Journal of Applied Physiology 108 (5), 1440-1446, 2010 | 27 | 2010 |
Virtual respiratory system for education and research: simulation of expiratory flow limitation for spirometry T Golczewski, M Darowski The International Journal of Artificial Organs 29 (10), 961-972, 2006 | 26 | 2006 |
Development of an Electronic Manometer for Intrapleural Pressure Monitoring R Krenke, M Guć, EM Grabczak, M Michnikowski, KJ Pałko, R Chazan, ... Respiration 82 (4), 377-385, 2011 | 21 | 2011 |
Cough during therapeutic thoracentesis: friend or foe? M Zielinska‐Krawczyk, M Michnikowski, EM Grabczak, KJ Palko, ... Respirology 20 (1), 166-168, 2015 | 16 | 2015 |
Physiologic basis of symptoms in pleural disease EM DeBiasi, D Feller-Kopman Seminars in Respiratory and Critical Care Medicine 40 (03), 305-313, 2019 | 15 | 2019 |
The respirator as a user of virtual lungs T Golczewski, M Kozarski, M Darowski Biocybernetics and Biomedical Engineering 23 (2), 57-66, 2003 | 15 | 2003 |
Patterns of pleural pressure amplitude and respiratory rate changes during therapeutic thoracentesis M Zielinska-Krawczyk, EM Grabczak, M Michnikowski, K Zielinski, ... BMC Pulmonary Medicine 18, 1-9, 2018 | 13 | 2018 |
Model studies on respiratory parameters for different lung structures. Part I. Theoretical consideration M Darowski, M Kozarski, T Golczewski Biocybernetics and Biomedical Engineering 20 (2), 67-77, 2000 | 11 | 2000 |
The use of a virtual patient to follow changes in arterial blood gases associated with therapeutic thoracentesis AM Stecka, T Gólczewski, EM Grabczak, K Zieliński, M Michnikowski, ... The International Journal of Artificial Organs 41 (11), 690-697, 2018 | 10 | 2018 |
The use of a virtual patient to follow pleural pressure changes associated with therapeutic thoracentesis T Gólczewski, AM Stecka, M Michnikowski, EM Grabczak, P Korczyński, ... The International Journal of Artificial Organs 40 (12), 690-695, 2017 | 10 | 2017 |
Virtual respiratory system in investigation of CPAP influence on optimal breathing frequency in obstructive lungs disease T Golczewski, M Darowski Nonlinear Biomedical Physics 1, 1-9, 2007 | 10 | 2007 |
Gas exchange in a virtual respiratory system-simulation of ventilation without lung movement T Gólczewski The International Journal of Artificial Organs 30 (12), 1047-1056, 2007 | 9 | 2007 |
A vector based approach to age-related changes of Doppler velocity waveforms in the brachial artery T Gólczewski, A Krajewski Ultrasound in medicine & biology 13 (1), 15-18, 1987 | 9 | 1987 |
Influence of ventilation mode on blood oxygenation-Investigation with Polish Virtual Lungs and Italian model of circulation T Gólczewski, K Zieliński, G Ferrari, KJ Pałko, M Darowski Biocybern Biomed Eng 30 (1), 17-30, 2010 | 7 | 2010 |
Influence of ventilatory mode on respiration parameters-investigation on virtual lungs T Golczewski, M Darowski Biocybernetics and Biomedical Engineering 23 (3), 63-72, 2003 | 7 | 2003 |
Spirometry: quantification of the shape of the maximal expiratory flow-volume curve T Gólczewski, W Lubiński Biocybern Biomed Eng 28 (3), 19-30, 2008 | 6 | 2008 |
The impact of early therapeutic intervention on the central pattern generator in premature newborns–a preliminary study and literature review M Czajkowska, A Fonfara, B Królak-Olejnik, M Michnikowski, ... Journal of Mother and Child 23 (3), 178-183, 2019 | 5 | 2019 |
VirRespir—an application for virtual pneumonological experimentation and clinical training K Zieliński, A Stecka, T Gólczewski World Congress on Medical Physics and Biomedical Engineering 2018: June 3-8 …, 2019 | 5 | 2019 |
A hybrid model of the respiratory system M Michnikowski, J Glapiński, M GUĆ, T Golczewski, M Darowski Biocybernetics and Biomedical Engineering 29 (1), 71-80, 2009 | 5 | 2009 |