Accurate and efficient intracranial hemorrhage detection and subtype classification in 3D CT scans with convolutional and long short-term memory neural networks M Burduja, RT Ionescu, N Verga Sensors 20 (19), 5611, 2020 | 105 | 2020 |
Convolutional neural networks with intermediate loss for 3D super-resolution of CT and MRI scans MI Georgescu, RT Ionescu, N Verga IEEE Access 8, 49112-49124, 2020 | 63 | 2020 |
Multimodal multi-head convolutional attention with various kernel sizes for medical image super-resolution MI Georgescu, RT Ionescu, AI Miron, O Savencu, NC Ristea, N Verga, ... Proceedings of the IEEE/CVF winter conference on applications of computer …, 2023 | 47 | 2023 |
Cancer treatment with hyperthermia D Sardari, N Verga INTECH Open Access Publisher, 2011 | 42 | 2011 |
Magnetic nanoparticles for magneto-resonance imaging and targeted drug delivery J Neamtu, N Verga Digest Journal of Nanomaterials and Biostructures 6 (3), 969-978, 2011 | 33 | 2011 |
Cytran: Cycle-consistent transformers for non-contrast to contrast ct translation NC Ristea, AI Miron, O Savencu, MI Georgescu, N Verga, FS Khan, ... arXiv preprint arXiv:2110.06400 1, 2021 | 24 | 2021 |
Calculation of externally applied electric field intensity for disruption of cancer cell proliferation D Sardari, N Verga Electromagnetic biology and medicine 29 (1-12), 26-30, 2010 | 15 | 2010 |
CyTran: a cycle-consistent transformer with multi-level consistency for non-contrast to contrast CT translation NC Ristea, AI Miron, O Savencu, MI Georgescu, N Verga, FS Khan, ... Neurocomputing 538, 126211, 2023 | 13 | 2023 |
Advantages of laser photoacoustic spectroscopy in radiotherapy characterization C Popa, N Verga, M Patachia, S Banita, C Matei, D Dumitras Rom. Rep. Phys 66 (1), 120-126, 2014 | 12 | 2014 |
Absorbed dose distributions using the isodensitometric method for exposures with filter employed for mammographies F Scarlat, A Scarisoreanu, N Verga Rom. Rep. Phys 65 (1), 168-177, 2013 | 10 | 2013 |
The effect of the ionizing radiation on hydroxyapatite–polydimethylsiloxane layers A Groza, SL Iconaru, G Jiga, P Chapon, S Gaiaschi, N Verga, M Beuran, ... Polymer Engineering & Science 59 (12), 2406-2412, 2019 | 9 | 2019 |
Implementing BNCT through the use of an electron accelerator SF Zarma, DA Mirea, I BUSCĂ, MN Poroschianu, N Verga Rom Rep Phys 66 (1), 182-191, 2014 | 6 | 2014 |
A new version of Hyper-Fractal Analysis:. Net WPF module for RGB 3D reconstruction of medical three-channel images IV Grossu, M Opritescu, O Savencu, AI Miron, M Verga, N Verga Computer physics communications 276, 108335, 2022 | 4 | 2022 |
Medical module for hyper-fractal analysis IV Grossu, O Savencu, AI Miron, C Besliu, N Verga Computer Physics Communications 273, 108255, 2022 | 4 | 2022 |
Ionization chamber dosimetry for conventional and laser-driven clinical hadron beams F Scarlat Journal of Biosciences and Medicines 3 (04), 8, 2015 | 4 | 2015 |
Optical coherence tomography in oncological imaging N Verga, DA Mirea, Busca, I, MN Poroschianu, SF Zarma, L Grinisteanu, ... Romanian Reports in Physics 66 (1), 75-86, 2014 | 4 | 2014 |
Evaluation of physical parameters for laser-driven clinical hadron beams F Scarlat, A Scarisoreanu, N Verga, F Scarlat, C Vancea Journal of Intense pulsed Lasers and Applications in Advances Physics 4, 55-64, 2014 | 4 | 2014 |
Absorbed dose determination in conventional and Laser-driven hadron clinical beams using electrical charge measurements F Scarlet, N Verga, A Scarisoreanu, E Badita, M Demeter, E Stancu, ... Romanian Reports in Physics 68 (1), 210-219, 2016 | 2 | 2016 |
Physical modeling of cancer tumor growth: A preliminary review D Sardari, N Verga, A Arbabi, A Ameri, S Amirifar Australian Journal of Basic and Applied Sciences 3 (4), 3531-3536, 2009 | 2 | 2009 |
A physical model for study of electromagnetic field interaction with cancer cell D Sardari, N Verga Prog Electromagn Res Symp 2, 891-893, 2008 | 2 | 2008 |