Validation of a new blood-mimicking fluid for use in Doppler flow test objects KV Ramnarine, DK Nassiri, PR Hoskins, J Lubbers Ultrasound in medicine & biology 24 (3), 451-459, 1998 | 393 | 1998 |
Numerical investigation of physiologically realistic pulsatile flow through arterial stenosis Q Long, XY Xu, KV Ramnarine, P Hoskins Journal of biomechanics 34 (10), 1229-1242, 2001 | 289 | 2001 |
The EFSUMB guidelines and recommendations for the clinical practice of elastography in non-hepatic applications: update 2018 A Săftoiu, OH Gilja, PS Sidhu, CF Dietrich, V Cantisani, D Amy, ... Ultraschall in der Medizin-European Journal of Ultrasound 40 (04), 425-453, 2019 | 271 | 2019 |
Assessment of the acoustic properties of common tissue-mimicking test phantoms JE Browne, KV Ramnarine, AJ Watson, PR Hoskins Ultrasound in medicine & biology 29 (7), 1053-1060, 2003 | 264 | 2003 |
Determining the relationship between three‐dimensional power Doppler data and true blood flow characteristics: an in‐vitro flow phantom experiment NJ Raine‐Fenning, NM Nordin, KV Ramnarine, BK Campbell, JS Clewes, ... Ultrasound in Obstetrics and Gynecology: The Official Journal of the …, 2008 | 186 | 2008 |
Development of an example flow test object and comparison of five of these test objects, constructed in various laboratories. SUG Teirlinck CJ1, Bezemer RA, Kollmann C, Lubbers J, Hoskins PR, Ramnarine ... Ultrasonics 36 (1-5), 653-60, 1998 | 185 | 1998 |
Evaluation of the effect of machine settings on quantitative three‐dimensional power Doppler angiography: an in‐vitro flow phantom experiment NJ Raine‐Fenning, NM Nordin, KV Ramnarine, BK Campbell, JS Clewes, ... Ultrasound in Obstetrics and Gynecology: The Official Journal of the …, 2008 | 167 | 2008 |
Construction and geometric stability of physiological flow rate wall-less stenosis phantoms KV Ramnarine, T Anderson, PR Hoskins Ultrasound in medicine & biology 27 (2), 245-250, 2001 | 148 | 2001 |
Shear wave elastography imaging of carotid plaques: feasible, reproducible and of clinical potential KV Ramnarine, JW Garrard, B Kanber, S Nduwayo, TC Hartshorne, ... Cardiovascular ultrasound 12, 1-9, 2014 | 135 | 2014 |
Noninvasive simultaneous assessment of wall shear rate and wall distension in carotid arteries P Tortoli, T Morganti, G Bambi, C Palombo, KV Ramnarine Ultrasound in Medicine & Biology 32 (11), 1661-1670, 2006 | 98 | 2006 |
Shear wave elastography assessment of carotid plaque stiffness: in vitro reproducibility study KV Ramnarine, JW Garrard, K Dexter, S Nduwayo, RB Panerai, ... Ultrasound in medicine & biology 40 (1), 200-209, 2014 | 95 | 2014 |
Embolus trajectory through a physical replica of the major cerebral arteries EML Chung, JP Hague, MA Chanrion, KV Ramnarine, E Katsogridakis, ... Stroke 41 (4), 647-652, 2010 | 82 | 2010 |
Shear wave elastography may be superior to greyscale median for the identification of carotid plaque vulnerability: a comparison with histology JW Garrard, P Ummur, S Nduwayo, B Kanber, TC Hartshorne, KP West, ... Ultraschall in der Medizin-European Journal of Ultrasound 36 (04), 386-390, 2015 | 81 | 2015 |
Doppler backscatter properties of a blood-mimicking fluid for Doppler performance assessment KV Ramnarine, PR Hoskins, HF Routh, F Davidson Ultrasound in medicine & biology 25 (1), 105-110, 1999 | 65 | 1999 |
Tissue Doppler imaging of carotid plaque wall motion: a pilot study KV Ramnarine, T Hartshorne, Y Sensier, M Naylor, J Walker, AR Naylor, ... Cardiovascular Ultrasound 1, 1-15, 2003 | 60 | 2003 |
Hardness and ultrasonic characteristics of the human crystalline lens H Tabandeh, M Wilkins, G Thompson, D Nassiri, A Karim Journal of Cataract & Refractive Surgery 26 (6), 838-841, 2000 | 60 | 2000 |
Anatomical flow phantoms of the nonplanar carotid bifurcation, part II: experimental validation with Doppler ultrasound S Meagher, TL Poepping, KV Ramnarine, RA Black, PR Hoskins Ultrasound in medicine & biology 33 (2), 303-310, 2007 | 57 | 2007 |
Angle-independent estimation of maximum velocity through stenoses using vector Doppler ultrasound R Steel, KV Ramnarine, F Davidson, PJ Fish, PR Hoskins Ultrasound in medicine & biology 29 (4), 575-584, 2003 | 46 | 2003 |
Enhanced detection of thromboemboli with the use of targeted microbubbles MJ Martin, EML Chung, AH Goodall, AD Martina, KV Ramnarine, L Fan, ... Stroke 38 (10), 2726-2732, 2007 | 45 | 2007 |
Improved characterisation of focal liver tumours: dynamic power Doppler imaging using NC100100 echo-enhancer KV Ramnarine, K Kyriakopoulou, P Gordon, NW McDicken, CS McArdle, ... European Journal of Ultrasound 11 (2), 95-104, 2000 | 43 | 2000 |