[PDF][PDF] Double element ultrasonic piezoceramic transducer modeling with VHDL-AMS: application to B/A nonlinear ultrasonic parameter measurement in pulse-echo …

R Guelaz, D Kourtiche, M Nadi, P Roth - Electronic Journal, Technical …, 2005 - ejta.org
This paper presents an ultrasonic transducer modeling with VHDL-AMS standard (Very High
speed integrated circuits Hardware Description Language–Analog and Mixed Signal) …

Finite difference modeling of the ultrasonic field radiated by circular transducers

A ALIA, H Djelouah, N Bouaoua - Journal of Computational …, 2004 - World Scientific
In this paper, FD formulations in cylindrical coordinates are used to model the field radiated,
by a circular source, in fluid and solid media. The stability of the used schemes is controlled …

The influence of pulser parameters on the transmission response of piezoelectric transducers

G Hayward - Ultrasonics, 1985 - Elsevier
A model is presented for the analysis of thickness-mode piezoelectric transmitters under
practical operating conditions. The systems feedback approach is employed to clearly …

Virtual design of medical transducers

W Cao - Medical Imaging 1998: Ultrasonic Transducer …, 1998 - spiedigitallibrary.org
Computer simulation has been used widely in medical ultrasonic transducer designs. One
could now construct and test an transducer entirely ion a virtual basis. Such a virtual design …

Modeling the acoustic field of physiotherapy ultrasound transducers using non uniform acoustic pressure distributions

MI Gutierrez, L Leija, A Vera - 2010 7th International …, 2010 - ieeexplore.ieee.org
In ultrasonic physiotherapy, the therapeutic effect is produced in the first 5 cm, into the
Fresnel zone. Models are focused principally in the Fraunhofer zone which is too far from the …

[引用][C] A new model of a piezoelectric transducer for direct impulse response evaluation

D Dotti - IEEE Transactions on Sonics and Ultrasonics, 1975 - ieeexplore.ieee.org
A new model of ultra-acoustic transducer is described, which allows the time response to a
voltage pulse to be evaluated directly. The analysis performed refers to the emission of …

[PDF][PDF] Development of ultrasonic transducer testing austenitic stainless steel weld

C Yubao - 17th World Conference on Non-destructive Testing …, 2008 - ndt.net
A transducer, as applied to ultrasonic testing, is the means by which electrical energy is
converted into acoustic energy and back again. The device, adapted for UT, has been called …

Advanced Designs of Ultrasonic Transducers and Devices Using Finite Element Analysis

FB Stulen, RB Francini - Ultrasonics, 2008 - taylorfrancis.com
Ultrasonic converters, horns, and nondestructive inspection transducers can be accurately
designed using the one dimensional (1D) wave equation. The segments that form the …

Theoretical simulation of the behavior of micromachined electrostatic ultrasonic transducers

LF Ge - Theoretical And Computational Acoustics 2001, 2002 - World Scientific
A general three-dimensional (3D) theoretical model for simulating the behaviour of
micromachined electrostatic ultrasonic transducers has been developed. The model takes …

[PDF][PDF] Design optimization analysis of a standing wave ultrasonic linear actuator

JM Fernandez, Y Ruffieux… - IEEE Ultrasonics …, 2005 - researchgate.net
The design, properties and optimization of an ul-trasonic actuator are presented. Numerical
modeling has been carried out and simulations with the FEM Ansys software have been …