[PDF][PDF] Experimental and Analytical Study of Seismically Isolated Structures with Uplift Prevention

P Roussis - Student Research Accomplishments 2002–2003, 2003 - nehrpsearch.nist.gov
Experimental and analytical studies of a seismically isolated five-story model structure are
conducted to understand the behavior of a novel uplift-prevention Friction Pendulum …

[PDF][PDF] Experimental and analytical study of seismically isolated structures with uplift restraint

P Roussis, M Constantinou - Proc., 13th World Conf. on Earthquake …, 2004 - iitk.ac.in
Experimental and analytical studies of a seismically isolated 5-story model structure are
conducted to understand the behavior of a novel uplift-prevention Friction Pendulum …

Experimental and analytical studies of structures seismically isolated with an uplift‐restraining friction pendulum system

PC Roussis, MC Constantinou - Earthquake engineering & …, 2006 - Wiley Online Library
This paper presents findings from a comprehensive analytical and experimental study on the
uplift‐restraining XY‐FP sliding isolation system. To investigate the effectiveness of the XY …

Uplift‐restraining friction pendulum seismic isolation system

PC Roussis, MC Constantinou - Earthquake engineering & …, 2006 - Wiley Online Library
This paper extends the scope of seismic isolation by introducing an innovative uplift‐
restraining Friction Pendulum system. Termed the XY‐FP isolator, the new isolation device …

Seismic behavior of a newly developed base isolation system for houses

B Myslimaj, M Midorikawa, M Iiba… - Journal of Asian …, 2002 - jstage.jst.go.jp
The good performance of seismically isolated structures during the 1995 Kobe earthquake
persuaded structural engineers, isolator manufacturers and housing construction companies …

[PDF][PDF] Development of a friction pendulum bearing base isolation system for earthquake engineering education

N Kravchuk, R Colquhoun, A Porbaha - Proceedings of the 2008 …, 2008 - academia.edu
Base isolation systems have become a significant element of a structural system to enhance
reliability during an earthquake. One type of base isolation system is Friction Pendulum …

[PDF][PDF] NCEER-Taisei Corporation research program on sliding seismic isolation systems for bridges: experimental and analytical study of a friction pendulum system …

MC Constantinou, P Tsopelas, YS Kim, S Okamoto - 1993 - nehrpsearch.nist.gov
The National Center for Earthquake Engineering Research (NCEER) was established to
expand and disseminate knowledge about earthquakes, improve earthquake-resistant …

Essential facility benefits from new base isolation technology

S Huang, M Skokan, S Islam - Structures Congress 2006: Structural …, 2006 - ascelibrary.org
A common problem that is encountered in the design of low-rise base-isolated buildings is
the resistance to uplift. Rubber isolators have low tension stiffness and strength and …

Experimental study of sliding isolated structures with uplift restraint

S Nagarajaiah, AM Reinhorn… - Journal of Structural …, 1992 - ascelibrary.org
An experimental study, performed to evaluate the feasibility of using a sliding isolation
system with uplift restraint devices for medium-rise buildings subject to column uplift, is …

Modelling aspects of structures isolated with the frictional pendulum system

JL Almazán, JC De La Llera… - … engineering & structural …, 1998 - Wiley Online Library
Different modelling aspects of structures isolated using the frictional pendulum system and
subjected to earthquake ground motions are studied herein. Although the vertical dynamics …