Seismic risk assessment of liquid storage tanks via a nonlinear surrogate model

K Bakalis, D Vamvatsikos… - Earthquake Engineering …, 2017 - Wiley Online Library
… A performance-based earthquake engineering approach is developed for the seismic risk
assessment of fixed-roof atmospheric steel liquid storage tanks. The proposed method is …

Seismic risk assessment of storage tanks in Turkish industrial facilities

KA Korkmaz, A Sari, AI Carhoglu - Journal of Loss Prevention in the …, 2011 - Elsevier
… The refinery also serves as a major port for liquid natural gas (… facilities, storage tanks,
cooling towers, stacks, and crude oil processing units. The fire, which exhausted all on-site water

Risk assessment and early warning systems for industrial facilities in seismic zones

E Salzano, AG Agreda, A Di Carluccio… - Reliability Engineering & …, 2009 - Elsevier
… for risk assessment. Some results of seismic analysis of atmospheric storage tanks are also
… Implications of recent nonlinear analyses on earthquake standards of liquid storage tanks. In…

Vector-valued intensity measures for seismic risk assessment of base-isolated liquid storage tanks

KK Sengar, SK Saha, M Gade - ASCE-ASME Journal of Risk and …, 2023 - ascelibrary.org
… estimate the probable seismic risk to a structure. … seismic risk assessment of base-isolated
liquid storage tanks. The presented results can be used for efficient assessment of seismic risk

Seismic intensity measures for above‐ground liquid storage tanks

K Bakalis, M Kohrangi… - Earthquake Engineering …, 2018 - Wiley Online Library
… to determine their suitability within the seismic risk assessment of liquid storage tanks. Using
a surrogate modelling approach on a squat tank that is examined under both anchored and …

Seismic risk assessment of liquid overtopping in a steel storage tank equipped with a single deck floating roof

S Caprinozzi, F Paolacci, M Dolšek - Journal of Loss Prevention in the …, 2020 - Elsevier
… Thus, research on the dynamic behaviour of steel storage tanks with floating roofs is still
required. In this paper, the seismic risk against liquid overtopping in a real steel storage tank

Structural issues in seismic risk assessment of existing oil storage tanks

G Fabbrocino, I Iervolino, G Manfredi - WIT Transactions on Modelling …, 2002 - witpress.com
storage facilities have to contain five thousands tons of liquid to be considered as “at risk” and
50.000 for “relevant risk”. … industrial risk plants are chemical or petrochemical facilities and …

[PDF][PDF] Seismic Reliability Assessment of Liquid Storage Tanks

K Bakalis, D Vamvatsikos, M Fragiadakis - … Conference on Earthquake …, 2014 - Citeseer
facilities is still at the academic level. This study provides an insight on the seismic risk
assessment of liquid storage tanks using a … for the seismic risk assessment of liquid storage tanks. …

Quantitative risk analysis of oil storage facilities in seismic areas

G Fabbrocino, I Iervolino, F Orlando… - Journal of hazardous …, 2005 - Elsevier
seismic risk into quantitative probabilistic seismic risk … oil storage plant with a number of
atmospheric steel tanks containing … intensity measures for seismic risk assessment of structures …

Seismic vulnerability assessment of base isolated liquid storage tanks under near-fault ground motions

M Farajian, N Saeed, WH Kang - Structures, 2022 - Elsevier
seismic fragility curves of base-isolated liquid storage tanks under near-fault ground motions.
This study also considers the non-isolated condition for comparison purpose. The failure …