Seismic vulnerability of above-ground storage tanks with unanchored support conditions for Na-tech risks based on Gaussian process regression

HN Phan, F Paolacci, R Di Filippo, OS Bursi - Bulletin of Earthquake …, 2020 - Springer
… A reliable seismic vulnerability assessment of steel storage … is conducted on an existing
unanchored steel storage tank. Special … lead to a biased vulnerability assessment. Moreover, the …

Multi-hazard coupling vulnerability analysis for buckling failure of vertical storage tank: Floods and hurricanes

M Huang, G Chen, P Yang, K Hu, L Zhou, J Men… - Process Safety and …, 2022 - Elsevier
… Furthermore, the vulnerability of vertical storage tanks under different wind speeds, …
parameters used for vulnerability assessment. Section 4 illustrates the vulnerability analysis under …

[HTML][HTML] Vulnerability Assessment of Process Vessels in the Event of Hurricanes

N Khakzad - Natural Hazards-New Insights, 2022 - intechopen.com
… techniques deliver inaccurate results, which in turn lead to inaccurate risk assessment and
… , and risk assessment. In this chapter, applications of BN to vulnerability assessment and …

Probabilistic seismic demand model and fragility estimates for critical failure modes of un-anchored steel storage tanks in petroleum complexes

F Berahman, F Behnamfar - Probabilistic Engineering Mechanics, 2009 - Elsevier
… Estimation of seismic vulnerability of existing equipment in … In this paper un-anchored steel
storage tanks, which is among the … Bayesian statistical technique to assess the specific critical …

Vulnerability-based design of sliding concave bearings for the seismic isolation of steel storage tanks

HN Phan, F Paolacci… - Pressure Vessels …, 2016 - asmedigitalcollection.asme.org
… have been recently extended to liquid storage tanks. Although the … vulnerability-based
design approach of a sliding concave bearing system for an existing elevated liquid steel storage

[PDF][PDF] PRELIMInARy SEISMIC vULnERAbILIty ASSESSMEnt of A StEEL oIL StoRAGE tAnK: GEoPhySICAL AnALySIS And dESIGn SPECtRA dEfInItIon

M Massa, P Augliera, S Carannante, M Cattaneo… - researchgate.net
… In this paper, it is presented a case study of a 10000 m3 hydrocarbon buffer storage tank,
belonging to the pipeline system owned by the Società Italiana Oleodotto Transalpino (SIOT), …

[PDF][PDF] Building Vulnerability Assessment Process in Bangladesh

MA Ansary - icpaceruet.org
… ▪ Obtain reliable data on steel grade or arrange testing of steel rebar (if possible) or assume
40 grades conservatively for using in all analysis/design adequacies. ▪ Use loading and …

[PDF][PDF] Vulnerability assessment of chemical facilities under the impact of floods

N Khakzad, P van Gelder - 27th European Safety and Reliability …, 2017 - researchgate.net
… where ρw, ρs, and ρl are the densities of the flood water, tank shell (usually steel), and the
… Fragility assessment of above ground petroleum storage tanks under storm surge. 12th …

Vulnerability to Perforation from Shooting Attacks of Tanks Storing Hazardous Materials

M Iaiani, R Sorichetti, A Tugnoli… - Chemical Engineering …, 2022 - cetjournal.it
… and used to assess the vulnerability to perforation of steel atmospheric storage tanks when
… Argenti F., Landucci G., Reniers G., Cozzani V., 2018, Vulnerability assessment of chemical …

[PDF][PDF] Seismic vulnerability of standardised industrial components: application to oil storage tanks

I Iervolino, G Fabbrocino, G Manfredi - Proc. 13th World Conference on …, 2004 - Citeseer
… for seismic vulnerability assessment of standardized … Sometimes failure of storage tanks
caused disastrous … Welded on grade steel tanks for oil storage can experience anchor failures or …