Effect of vertical acceleration on response of concrete rectangular liquid storage tanks

MR Kianoush, JZ Chen - Engineering structures, 2006 - Elsevier
… As the transverse vibration of the flexible wall can be significant, the dynamic response of
liquid storage tanks in the horizontal direction due to the vertical excitation is investigated in …

ICS solar systems with horizontal (E–W) and vertical (N–S) cylindrical water storage tank

Y Tripanagnostopoulos, M Souliotis - Renewable Energy, 2004 - Elsevier
vertical storage tank mounting in system trough and not to achieve high performance ICS
systems. In all experimental models we kept the same air gap between glazing and absorber (~…

Multi-hazard coupling vulnerability analysis for buckling failure of vertical storage tank: Floods and hurricanes

M Huang, G Chen, P Yang, K Hu, L Zhou, J Men… - Process Safety and …, 2022 - Elsevier
tank wall is verified by FLUENT software and the rationality of FLUENT simulation is shown
by laboratory experiments of vertical storage tanks… the vulnerability of storage tanks gradually …

[HTML][HTML] Using the acoustic emission method for testing aboveground vertical storage tank bottoms

A Olszewska - Applied Acoustics, 2022 - Elsevier
… The purpose of AE testing (AT) of the storage tank bottom is to detect and classify AE …
vertical storage tank bottoms and the results of tests carried out on three crude oil storage tanks. …

Unsteady numerical simulation of the cooling process of vertical storage tanks under laminar natural convection

I Rodriguez, J Castro, CD Perez-Segarra… - International Journal of …, 2009 - Elsevier
… , the unsteady natural convection inside a vertical storage tank submitted to heat losses to
the … range of working conditions for small storage tanks used in domestic hot water systems. …

Full‐scale shaking table test and numerical modeling of a 3000‐liter legged storage tank isolated with a vertical rocking isolation system

SI Reyes, JL Almazán, MF Vassiliou… - Earthquake …, 2022 - Wiley Online Library
… a vertical‐rocking isolation (VRI). This evaluation is done by 1‐D shaking table tests performed
on a full‐scale legged storage tank … one placed on each leg of the tank, which uses high‐…

Probabilistic seismic fragility assessment of vertical storage tank with a floating roof

M Wang, Z Sun, J Sun, L Cui, Y Wu - Structures, 2023 - Elsevier
Vertical storage tank is an important facility of oil depot, which may cause catastrophic … the
seismic fragility of tank with a floating roof. A refined finite element model of the tank with three …

Effect of wall flexibility on dynamic response of concrete rectangular liquid storage tanks under horizontal and vertical ground motions

AR Ghaemmaghami, MR Kianoush - Journal of structural …, 2010 - ascelibrary.org
In this study, the finite-element method is used to investigate the seismic behavior of
rectangular liquid tanks in two-dimensional space. This method is capable of considering both …

Thermal performance of a vertical solar hot water storage tank with a mantle heat exchanger depending on the discharging operation parameters

M Arslan, AA Igci - Solar Energy, 2015 - Elsevier
… In the present study, the transient thermal behavior of a vertical cylindrical thermal storage
tank of a solar collector system equipped with a mantle heat exchanger was investigated …

Response Surface Methodology-based prediction model for working fluid temperature during stand-alone operation of vertical cylindrical thermal energy storage tank

H Khurana, R Majumdar, SK Saha - Renewable Energy, 2022 - Elsevier
… In this study, a vertical stand-alone cylindrical storage tank is studied experimentally and
numerically. A two-dimensional numerical model of the stand-alone cylindrical storage tank is …