Optimization of a snapshot Mueller matrix polarimeter

P Lemaillet, S Rivet, B Le Jeune - Optics letters, 2008 - opg.optica.org
We report on the optimization of a snapshot Mueller matrix polarimeter performed by using
singular-value decomposition. The snapshot technique relies on wavelength polarization …

Accurate alignment of optical axes of a biplate using a spectroscopic Mueller matrix ellipsometer

H Gu, X Chen, H Jiang, C Zhang, W Li, S Liu - Applied Optics, 2016 - opg.optica.org
The biplate that consists of two single wave plates made from birefringent materials with
their fast axes oriented perpendicular to each other is one of the most commonly used …

The fixed-polarizer nulling scheme in generalized ellipsometry

RMA Azzam, TL Bundy, NM Bashara - Optics Communications, 1973 - Elsevier
In the polarizer-compensator-system-analyzer (PCSA) ellipsometer arrangement the nulling
scheme in which P is set and C and A are adjusted for null provides the largest number of …

Effect of nonpolarizing beam splitter on measurement error in heterodyne interferometric ellipsometers

Y Deng, X Li, Y Geng, X Hong - Measurement Science and …, 2012 - iopscience.iop.org
The nonlinear error of the ellipsometric parameters (EP) has been investigated by many
researchers in terms of the imperfection of polarizing beam splitters (PBS), the elliptical …

Simplified calibration procedure for Mueller polarimeter in transmission configuration

H Hu, E Garcia-Caurel, G Anna, F Goudail - Optics letters, 2014 - opg.optica.org
We address calibration of Mueller polarimeters in transmission configuration and in the
presence of noise. By comparing the maximum likelihood (ML) method and the extended …

Measurement of the Jones matrix of an optical system by return-path null ellipsometry

RMA Azzam - Optica Acta: International Journal of Optics, 1981 - Taylor & Francis
A return-path null ellipsometer (RPNE), whose polarizing/analysing optics (PAO) consist of a
linear polarizer and a linear quarter-wave retarder (QWR), provides only two independent …

Efficient acquisition of Mueller matrix via spatially modulated polarimetry at low light field

T Ning, X Ma, Y Li, Y Li, K Liu - Optics Express, 2023 - opg.optica.org
Mueller polarimetry performed in low light field with high speed and accuracy is important for
the diagnosis of living biological tissues. However, efficient acquisition of the Mueller matrix …

Multi-wavelength Mueller matrix polarimeter

L Jin, K Takizawa, Y Otani, N Umeda - Optical review, 2005 - Springer
The retardation of two quarter-wave plates designed for a particular wavelength decreases
or increases in accordance with the wavelength of input light beam. Compensating the …

Effect of input polarization states on the error of polarization measurement

H Dong, P Shum - Optical Engineering, 2008 - spiedigitallibrary.org
For measurements of the Mueller matrix and other polarization effect matrices in a
birefringent optical system, such as an optical fiber, we demonstrate by theoretical analysis …

Partial Mueller matrix polarimeter using liquid crystal modulators

M Salamaga, WA Woźniak - Applied Optics, 2023 - opg.optica.org
A simple partial Mueller polarimeter is described, consisting of two linear polarizers and two
liquid crystal variable retarders. The measurement leads to an incomplete Mueller–Scierski …