Second harmonic generation double stokes Mueller polarimetric microscopy of myofilaments

L Kontenis, M Samim, A Karunendiran… - Biomedical Optics …, 2016 - opg.optica.org
The experimental implementation of double Stokes Mueller polarimetric microscopy is
presented. This technique enables a model-independent and complete polarimetric …

Dual‐and single‐shot susceptibility ratio measurements with circular polarizations in second‐harmonic generation microscopy

A Golaraei, L Kontenis, A Karunendiran… - Journal of …, 2020 - Wiley Online Library
Polarization‐resolved second‐harmonic generation (P‐SHG) microscopy is a technique
capable of characterizing nonlinear optical properties of noncentrosymmetric biomaterials …

Unified theory for polarization analysis in second harmonic and sum frequency microscopy

XY Dow, EL DeWalt, JA Newman, CM Dettmar… - Biophysical …, 2016 - cell.com
A unified theoretical framework for the recovery of second-order nonlinear susceptibility
tensors and sample orientations from polarization-dependent second harmonic generation …

Third-harmonic generation Stokes-Mueller polarimetric microscopy

L Kontenis, M Samim, S Krouglov, V Barzda - Optics express, 2017 - opg.optica.org
An experimental implementation of the nonlinear Stokes-Mueller polarimetric (NSMP)
microscopy in third-harmonic generation modality is presented. The technique is able to …

Polarization ellipticity compensation in polarization second-harmonic generation microscopy without specimen rotation

CK Chou, WL Chen, PT Fwu, SJ Lin… - … of biomedical optics, 2008 - spiedigitallibrary.org
In imaging anisotropic samples with optical microscopy, a controlled, polarized light source
can be used to gain molecular information of fibrous materials such as muscles and …

In vivo, pixel-resolution mapping of thick filaments' orientation in nonfibrilar muscle using polarization-sensitive second harmonic generation microscopy

S Psilodimitrakopoulos, SICO Santos… - Journal of …, 2009 - spiedigitallibrary.org
The polarization dependence of second harmonic generation (SHG) microscopy is used to
uncover structural information in different muscle cells in a living Caenorhabditis elegans (C …

Studies of χ (2)/χ (3) tensors in submicron-scaled bio-tissues by polarization harmonics optical microscopy

SW Chu, SY Chen, GW Chern, TH Tsai, YC Chen… - Biophysical journal, 2004 - cell.com
Optical second-and third-harmonic generations have attracted a lot of attention in the
biomedical imaging research field recently due to their intrinsic sectioning ability and …

Collagen and myosin characterization by orientation field second harmonic microscopy

C Odin, T Guilbert, A Alkilani, OP Boryskina, V Fleury… - Optics express, 2008 - opg.optica.org
Collagen and myosin fibrils are endogenous harmonophores that both give rise to Second
Harmonic Generation (SHG). By combining four polarization SHG images provided by a …

Polarization anisotropy in fiber-optic second harmonic generation microscopy

L Fu, M Gu - Optics Express, 2008 - opg.optica.org
We report the investigation and implementation of a compact second harmonic generation
microscope that uses a single-mode fiber coupler and a double-clad photonic crystal fiber …

Polarization-resolved second harmonic generation microscopy with a four-channel Stokes-polarimeter

N Mazumder, J Qiu, MR Foreman, CM Romero… - Optics express, 2012 - opg.optica.org
We developed a four-channel photon counting based Stokes-polarimeter for spatial
characterization of polarization effects in second harmonic generation (SHG). We have …