account the experimental data. To investigate and visualize the evaporation procedure in
the coil, a mathematical pattern of the vapor-liquid mixture motion is compiled and
reproduced. In the methodology of the study of the movement of the steam-water mixture,
correction coefficients are proposed for calculating the velocities of the coolant in non-
standard coaxial coils. The parameters were calculated using data sensitivity analysis and …