[HTML][HTML] Comparative study of modified Mueller matrix transformation and polar decomposition parameters for transmission and backscattering tissue polarimetries

B Chen, Y Lan, H Zhai, L Deng, H He, H Mao, H Ma - Applied Sciences, 2021 - mdpi.com
… other when measuring complicated tissue samples containing layered anisotropic structures,
reducing the accuracy of Mueller matrix polarimetry for quantitative tissue evaluation. To …

Comparative study of Mueller matrix transformation and polar decomposition for optical characterization of turbid media

M Iqbal, I Ahmad, A Khaliq, S Khan - Optik, 2020 - Elsevier
Mueller matrix polar decomposition (MMPD) proposed by Lu and Chipman has received
significant attention and commonly used in polarimetry … demonstrates quantitative comparison …

Terahertz Mueller matrix polarimetry and polar decomposition

SX Huang, YS Zeng, GB Wu, KF Chan… - IEEE Transactions …, 2019 - ieeexplore.ieee.org
Quantitatively, the SSIM would be a good metric for evaluating the imaging performance.
The SSIM is one of the most superior metrics for image quality assessment (IQA) by quantifying …

Comparative study of 3 x 3 Mueller matrix transformation and polar decomposition

A Khaliq, S Ashraf, B Gul, I Ahmad - Optics Communications, 2021 - Elsevier
… usually differ quantitatively. … decomposition methods in Mueller matrix polarimetry. Specifically,
the optical polarization variables derived from the decomposition of a 3 × 3 Mueller matrix

Mueller matrix polarimetry and polar decomposition of articular cartilage imaged in reflectance

RN Huynh, G Nehmetallah, CB Raub - Biomedical Optics Express, 2021 - opg.optica.org
… a laser-based Mueller matrix imaging polarimeter in reflection, … instrument and tested the
accuracy of polar decomposition … We hypothesized that the polar decomposition maps would …

Mueller matrix polarimetry—an emerging new tool for characterizing the microstructural feature of complex biological specimen

H He, R Liao, N Zeng, P Li, Z Chen… - Journal of Lightwave …, 2018 - ieeexplore.ieee.org
… In 1996 Lu and Chipman proposed the Mueller matrix polar decomposition (MMPD) scheme…
As a label-free, non-invasive and quantitative tool, Mueller matrix polarimetry has been …

Mueller matrix polarimetry for characterization of skin tissue samples: A review

I Ahmad, A Khaliq, M Iqbal, S Khan - Photodiagnosis and photodynamic …, 2020 - Elsevier
… have been analyzed, quantitatively compared (using box and whisker plot and student t test…
, Lu-Chipman polar decomposition has been most commonly used in tissue polarimetry; we …

Multi-spectral Mueller matrix imaging polarimetry for studies of human tissues

T Novikova, J Rehbinder, S Deby… - Clinical and …, 2016 - opg.optica.org
… the polarimetric response of tissue can be quantitatively measured, … The polar decomposition
can be performed by different … Lu-Chipman [7] decomposition when Mueller matrix M of the …

[HTML][HTML] Flexible polarimetric probe for 3× 3 Mueller matrix measurements of biological tissue

S Forward, A Gribble, S Alali, AA Lindenmaier… - Scientific Reports, 2017 - nature.com
… example, help quantitatively differentiate healthy from pathologic tissue. However, most
bio-… , diattenuation, and depolarisation can be obtained from it via polar decomposition 18,19 . …

Accuracy assessment of tissue polarimetric properties based on Mueller matrix images decomposition

N Li, J Li, Y Li, G Zhou, J Wang - … International Conference on …, 2020 - spiedigitallibrary.org
… Fig.1 shows the schematic diagram of the experimental Mueller matrix polarimetry which can
… “Polar decomposition of 3 × 3 Mueller matrix: A tool for quantitative tissue polarimetry,” Opt. …