Three Phase Dynamic Simulation of Air Blast Generator Circuit Breakers--Theory and Modeling

NR Prasad, SR Herling - IEEE Transactions on Power …, 1982 - ieeexplore.ieee.org
Simulations of three-phase faults at the generator terminals have shown the existence of
non-zero currents in all three phases for several cycles. Particularly in the application of …

Multi-break arc interaction in the energy balance region

TM Smith, RG Colclaser - IEEE transactions on power delivery, 1988 - ieeexplore.ieee.org
It is postulated that the performance of a multi-break interrupter can be better than that
expected from an extrapolation of the test results on a single-break unit. A computer model …

A physical arc model for the simulation of current zero behavior of high-voltage circuit breakers

L Van der Sluis, WR Rutgers… - IEEE transactions on …, 1992 - ieeexplore.ieee.org
The equations and parameters of a physical arc model which can be used to compare test
circuits with respect to the thermal and dielectric interrupting interval of SF/sub 6/circuit …

Parameter determination for modeling system transients-Part VI: Circuit breakers

JA Martinez, J Mahseredjian… - IEEE Transactions on …, 2005 - ieeexplore.ieee.org
A detailed dynamic arc model may be used to roughly evaluate the interrupting capacity of a
breaker and its influence on the deformation of the interrupted current. In some cases the …

Effect of high-frequency currents on interrupting performance of GCBs

H Kawano, M Ishikawa, H Toda… - IEEE transactions on …, 1994 - ieeexplore.ieee.org
With electric power systems, it is shown by calculations that as the transmission voltage
rises, high-frequency components contained in the fault current could remain until current …

A half cycle air blast generator breaker for high power testing fields

K Kriechbaum - IEEE Transactions on Power Apparatus and …, 1972 - ieeexplore.ieee.org
Generator breakers in high-power testing fields, the back-up breakers, have the function of
safety breakers: they have to protect both the generator and the test breaker from being …

Comparison of test circuits for high-voltage circuit breakers by numerical calculations with arc models

L van der Sluis, WR Rutgers - IEEE transactions on Power …, 1992 - ieeexplore.ieee.org
The authors use a physical arc model to compare the switching behaviors of circuit breakers
in a direct and two synthetic test circuits with a computer program. It was found that not only …

Practical modeling of the circuit breaker arc as a short line fault interrupter

TE Browne - IEEE Transactions on Power Apparatus and …, 1978 - ieeexplore.ieee.org
The short-line fault interrupting ability of gas-blast circuit breakers is limited by arc energy
balance processes very close to current zero. Practical calculation of the energy balance …

A theoretical analysis of dynamic arcs and test results of model synchronous air blast circuit breakers

T Morita, M Iwashita, Y Nitta - IEEE Transactions on Power …, 1978 - ieeexplore.ieee.org
This paper reported analyzed results of the transient dynamic arc around current zero of air
blast circuit breakers on the basis of Mayr arc model. It was proved that an arc time constant …

[PDF][PDF] A proposed transient recovery voltage mitigation technique for generator-circuit-breaker fed faults

M Abdullah - J. Electr. Syst, 2013 - researchgate.net
Generator-fed fault currents are subjected to very demanding condition called “Delayed
current zeros”. This unique characteristic of the fault current comes from the very high X/R …