Analytical prediction of transient breakdown characteristics of SF/sub 6/gas circuit breakers

F Endo, M Sato, M Tsukushi, Y Yoshioka… - IEEE transactions on …, 1989 - ieeexplore.ieee.org
A study was conducted to estimate transient breakdown voltages (V/sub BD/s) between
contacts of a puffer-type SF/sub 6/gas circuit breaker. When contacts are opening …

Hot gas flow analysis in SF/sub 6/gas circuit breaker during the short circuit interruption

T Yoshizumi, K Ibuki, M Hosomi… - IEEE transactions on …, 1989 - ieeexplore.ieee.org
Characteristics of the hot gas flow in an SF/sub 6/gas circuit breaker during short-circuit
interruption are investigated both experimentally and theoretically, to achieve a more …

Dielectric withstand and breaking capacity of SF/sub 6/circuit breakers at low temperatures

M Landry, G St-Jean, R Jeanjean… - IEEE transactions on …, 1988 - ieeexplore.ieee.org
The influence of low temperatures on the dielectric withstand and the breaking capacity of a
puffer-type SF/sub 6/circuit breaker was studied. Results of a dielectric and breaking tests …

Analysis of the dielectric strength of an SF/sub 6/circuit breaker

JY Trepanier, M Reggio, Y Lauze… - IEEE Transactions on …, 1991 - ieeexplore.ieee.org
A computer model for predicting the time evolution of the dielectric strength of SF/sub
6/following the interruption of a small capacitance current in a puffer-type circuit breaker is …

An investigation of breakdown voltage with small arc current due to poor contact in SF/sub 6/gas

S Sugiyama, T Morita, T Hosokawa… - IEEE transactions on …, 1992 - ieeexplore.ieee.org
Using an experimental apparatus modeled for the contact portion of a gas insulated
switchgear (GIS), the influence of the distance between the portion and the dead tank of the …

A method of calculation of the puffer chamber pressure during current interruption of the puffer type gas circuit breaker

Y Yoshioka, M Tsukushi, K Natsui… - The transactions of the …, 1978 - jstage.jst.go.jp
電力用しゃ断器には, 様 々な源理方式のものがあるが, 大 容量器として最近発達の著しいのが
バッファ式の SF6 ガ スしゃ断器 (以 下バッファ式 GCB と 略す) である. 既に国内でも 550kV 50 kA …

Short-circuit testing method of 3-phase-in-one-tank-type SF/sub 6/gas circuit breaker

S Yamashita, N Miyake, K Suzuki… - IEEE transactions on …, 1989 - ieeexplore.ieee.org
The dielectric performance of the circuit breaker between poles after current interruption was
verified by testing. Test conditions based on IEC standards were examined. Based on these …

Behavior of inhomogeneous high-temperature SF/sub 6/gas in a gas circuit breaker

T Uchii, K Iwata, H Kawano… - 2001 IEEE Power …, 2001 - ieeexplore.ieee.org
The purpose of the present paper is to show the dielectric characteristics of inhomogeneous
hot SF/sub 6/gas in a gas circuit breaker (GCB) experimentally. High-temperature and low …

Effects of hot SF/sub 6/on post-arc circuit breaker design

T Uchii, S Nishiwaki, S Boggs - IEEE Transactions on Power …, 2004 - ieeexplore.ieee.org
SF/sub 6/is blown through the arc during interruption of an SF/sub 6/puffer circuit breaker.
This hot gas flows down an exhaust tube into the chamber of a dead tank circuit breaker …

Developing of 550 kV 1-break GCB. I. Investigation of interrupting chamber performance

K Suzuki, H Toda, A Aoyagi, H Ikeda… - IEEE transactions on …, 1993 - ieeexplore.ieee.org
The interrupting chamber for a 550 kV 1-break gas blast circuit breaker (GCB) is developed.
To cope with voltages and interrupting capacities of nearly double per break compared with …