Optimizing Coded Aperture Imaging techniques to allow for online tracking of fiducial markers with high‐energy scattered radiation from treatment beam

A Mahl, B Miller, M Miften, BL Jones - Medical Physics, 2020 - Wiley Online Library
… Current studies are investigating the imaging of lung tumors … of coded aperture scatter
imaging to produce internal imagesCoherent (Thomson) scattering was suppressed, as it added …

Compact and ultracompact spectral imagers: technology and applications in biomedical imaging

MH Tran, B Fei - Journal of biomedical optics, 2023 - spiedigitallibrary.org
… Since the last review of medical hyperspectral imaging from … to resolve the images obtained
from the coded aperture to the … 880 hyperspectral images of cholangiocarcinoma (cancer of …

Lens-loaded coded aperture with increased information capacity for computational microwave imaging

O Yurduseven, MAB Abbasi, T Fromenteze, V Fusco - Remote Sensing, 2020 - mdpi.com
… to achieve a coherent phase response across the aperture to raster scan the radiation pattern
of … scenario, the L-shaped phantom is modelled as a metal scatter with the reflectivity of the …

Multi-wavelength interference phase imaging for automatic breast cancer detection and delineation using diffuse reflection imaging

A Mahmoud, YH El-Sharkawy - Scientific Reports, 2024 - nature.com
… Many traditional coherent interference techniques like holography … that the use of blue light
can help to reduce scattering in the … 446.6 nm spectral image and the improved image quality …

Simulation based evaluation of a fan beam coded aperture x-ray diffraction imaging system for biospecimen analysis

S Stryker, AJ Kapadia… - Physics in Medicine & …, 2021 - iopscience.iop.org
coded aperture XRD imaging for fast, high-resolution scatter … right of the tissue represent
coherently scattered x-rays that … in terms of a potential application: cancer detection in excised …

[图书][B] Code aperture imaging from the visible to X-ray

EE Salazar - 2022 - search.proquest.com
… The size of the implemented sensor and coded aperture is 8 × 8. The dashed red circles
and red arrow indicate the dispersion process between bands. . . . . . . . . . . . . . . . . . . . . . . . . . …

[图书][B] X ray phase and coherent scatter imaging measurements

P Cheung - 2022 - search.proquest.com
coherent scatter signatures. … cancer surrogate. Therefore, as discussed in chapter 4, we
used samples of graphite, fat, breast cancer tissue and normal tissue for the coherent scattering

X-ray fan beam coded aperture transmission and diffraction imaging for fast material analysis

S Stryker, JA Greenberg, SJ McCall, AJ Kapadia - Scientific reports, 2021 - nature.com
image, whereas the scatter passes through a coded aperture … This hyperspectral image
allows for intensity throughout the … fan beam coded aperture imaging system, a breast cancer

Design and implementation of a miniaturized elastic scattering spectroscopy (mess) system with scanning modality for oral cancer deep margins assessment

AJ Gray - 2021 - search.proquest.com
… The goal of this thesis is the design and implementation of a low cost, portable and modular
… oral cancer samples. A low-cost ESS device has been developed and validated for use

Coded-aperture computational millimeter-wave image classifier using convolutional neural network

R Sharma, R Hussung, A Keil, F Friederich… - IEEE …, 2021 - ieeexplore.ieee.org
A millimeter-wave (mmW) classifier system applied to images synthesized from a coded-aperture
based computational imaging (CI) radar is presented. A developed physical model of a …