[HTML][HTML] Radiofrequency coils for low-field (0.18–0.55 T) magnetic resonance scanners: experience from a research lab–manufacturing companies cooperation

G Giovannetti, F Frijia, A Flori - Electronics, 2022 - mdpi.com
… In the case of tunnel-type resistive or superconductive magnets, the magnetic field (B 0 ) …
where the inductance L stands for the energy stored in the magnetic field, the capacitance C …

Laboratory Performance Measurement of Blowers with Electronically Commutated Motors in Horizontal Low-Profile Fan Coil Units.

P Yin, A McBride, B Derouen… - ASHRAE …, 2020 - search.ebscohost.com
… or direct expansion (DX) coils, optional electric heaters, one or … by ECMs, extensive laboratory
measurements have been … ECMs in FCUs to gather the laboratory data for performance …

Single-coil magnetic induction tomography using the LDC-1101 chip

JR Feldkamp, S Quirk - IEEE Sensors Journal, 2020 - ieeexplore.ieee.org
… Lattice type methods would likely require a robotic … or sub-features can help understand
whether random sampling is able to … Letting the vector c locate the coil center relative to the lab

[HTML][HTML] Experimental study of a coil type steam boiler operated on an oil field in the subarctic continental climate

K Osintsev, S Aliukov, S Kuskarbekova - Energies, 2021 - mdpi.com
… Flue gas velocity was measured in laboratory conditions using an experimental stand. The
aerodynamic characteristics of the fan were controlled by a frequency drive of the electric …

Laboratory setup for fault detection on overhead power lines based on magnetic field measurement

Đ Lekić, P Mršić, B Erceg, Č Zeljković… - 2020 International …, 2020 - ieeexplore.ieee.org
coils, analog amplifying and filtering circuits are described in detail. The developed laboratory
… in [1] for different fault types simulated with the laboratory setup described in this paper are …

Design and development of the S-band high power test stand for multi-purpose applications at IHEP

JD Liu, ZS Zhou, N Gan, X He, DY He… - Journal of …, 2022 - iopscience.iop.org
… It is worth mentioning that the different types of klystrons used in this test stand have … According
to different specifications of the klystron, three sets of focus coil power supplies have been …

[HTML][HTML] Conceptual design of a HTS dipole insert based on Bi2212 Rutherford cable

AV Zlobin, I Novitski, E Barzi - Instruments, 2020 - mdpi.com
… The maximum field in Bi2212 coils in various test configurations for two Bi2212 types of wires
at various levels (from 30% to zero) of cable I c degradation is summarized in Table 6. The …

First magnet operation on the cryogenic test stand Gersemi at FREIA

K Pepitone, K Gajewski, L Hermansson… - arXiv preprint arXiv …, 2021 - arxiv.org
… bench, installed at FREIA laboratory at Uppsala University, … allow two superconducting
magnet coils to be powered up to 2 … When a quench is detected the DAQ is triggered, two type of …

An experimental comparison of radiant wall and ceiling cooling system integrated with ground source heat pump and direct expansion fan coil system in a highly …

A Dogan, N Kayaci, H Demir, MK Sevindir - Energy and Buildings, 2022 - Elsevier
… area of 52.5 m 2 as a full scale laboratory. Air velocity, horizontal and vertical air temperature
… out with 23T-type thermocouples placed on 5 pieces of 2.5 m high metal stands (trees), the …

A real-time monitoring system for investigating electromagnetic behaviors of an HTS coil

J Bang, SH Park, J Park, G Kim, JT Lee… - IEEE Transactions …, 2022 - ieeexplore.ieee.org
coil, first, a single-pancake type coil was wound using 146 m long HTS tape. During the coil
… Each solid line with squares, circles, and triangles stand for, respectively, measured results, …