A voltage ride-through control based on coordination between energy storage and wind turbine

LIN Yi, T Yuchen, C Xunjun, H Hai… - Modern Electric …, 2023 - xddl.ncepujournal.com
In allusion to the voltage ride through of wind power generating units, a voltage fault ride-
through control method based on the coordinated control of energy storage and rotor of wind …

Research on zero-voltage ride through control strategy of doubly fed wind turbine

K Qin, S Wang, Z Kang - Energies, 2021 - mdpi.com
With the rapid increase in the proportion of the installed wind power capacity in the total grid
capacity, the state has put forward higher and higher requirements for wind power …

Research on fault ride-through capacity of direct driven wind turbine with permanent magnet synchronous generator under grid asymmetric faults

X Zhang, Z Cheng, Y Guo, X Wang - Journal of Renewable and …, 2014 - pubs.aip.org
The problem that negative sequence component of dc-link voltage will produce second
oscillation under grid asymmetric faults for direct driven wind turbine with permanent magnet …

[HTML][HTML] A coordinated and steadily fault ride through strategy under short-circuit fault of the wind power grid connected system based on the grid-forming control

J Hu, Y Chi, X Tian, Y Zhou, W He - Energy Reports, 2022 - Elsevier
With the continuous improvement of the penetration level of wind power in the power
system, the grid-forming mode of wind turbine will gradually become one of the main modes …

Simulation study on dynamic response of doubly fed induction generators during system voltage sag caused by power grid faults

XL Wang, WY Sun - 2010 - ir.lut.edu.cn
摘要 To research the dynamic response of wind power generation unit under certain grid
voltage sag in depth, taking single doubly-fed induction generator (DFIGs) with capacity of 1 …

L/HVRT scheme of offshore permanent magnet synchronous wind turbine

J Fu, X Yan, D Wang, H Liu, D Cheng - 2022 - IET
A low/high voltage fault ride through technology scheme of offshore permanent magnet
synchronous wind turbine generator (PMSG) is proposed. When the offshore PMSG …

[PDF][PDF] Coordinated Rotor-Side Control Strategy for Doubly-Fed Wind Turbine under Symmetrical and Asymmetrical Grid Faults

Q Yan, C Yuan, W Gu, Y Liu, Y Tang - Energy Engineering, 2023 - cdn.techscience.cn
In order to solve the problems of rotor overvoltage, overcurrent and DC side voltage rise
caused by grid voltage drops, a coordinated control strategy based on symmetrical and …

[引用][C] Power control strategy of directly driven wind turbine with energy storage system

K Zhang - Diangong Jishu Xuebao(Transactions …, 2011 - Chinese Machine Press,| a 1 Nanjie …

[引用][C] Coordinated var-voltage control during fault of wind power system

C Wang, J Liang, J Feng, Y Niu… - Electric Power …, 2011 - … 38 New Mofan Malu Nanjing 210003 …

[引用][C] Application of crowbar circuit in grid fault riding through for doubly-fed induction wind power generation system

W Ma - Electric Power Automation Equipment, 2011 - … 38 New Mofan Malu Nanjing 210003 …