[HTML][HTML] Local loss model of dividing flow in a bifurcate tunnel with a small angle

X Zhang, T Zhang, Y Hou, K Zhu, Z Huang… - J. Zhejiang Univ. Sci …, 2019 - jzus.zju.edu.cn
To provide a theoretical basis for the flow diversion control of a bifurcate tunnel, the flow
separation characteristics and local loss model at the tunnel bifurcation were analyzed by …

An experimental study on the influence of local loss on ventilation characteristic of dividing flow in urban traffic link tunnel

X Wang, M Wang, P Qin, T Yan, J Chen, T Deng… - Building and …, 2020 - Elsevier
In order to deeply study the local ventilation loss coefficient of the bifurcation structure in
urban traffic link tunnel, a scale 1: 50 model with bifurcation structure was designed and …

Numerical study on the mean velocity distribution law of air backflow and the effective interaction length of airflow in forced ventilated tunnels

C Nan, J Ma, Z Luo, S Zheng, Z Wang - Tunnelling and Underground …, 2015 - Elsevier
The effective interaction length of airflow (L e) is the key factor in the determination of the
distance between an air duct nozzle and the working face in dead-end tunnels. At present …

Diffusion characteristics of airflow and CO in the dead-end tunnel with different ventilation parameters after tunneling blasting

J Wang, Y Xue, J Xiao, D Shi - Acs Omega, 2023 - ACS Publications
After tunnel blasting, a large amount of CO will be produced and accumulated in the dead-
end tunnel. If the ventilation discharge is not proper and the entry time into the dead-end …

Field test and numerical simulation study on energy loss coefficient of vehicle cross-passage area in twin-tunnels

X Yan, J Li, X Ye, Y Zeng, Y Fang, Y Bai - Tunnelling and Underground …, 2020 - Elsevier
The energy loss coefficient is a key parameter for tunnel ventilation design because it affects
the distribution of airflow in the case of a fire. It is critical to discover the variation of the …

Study on Mechanism of Series-Flow of Pollutants between Consecutive Tunnels by Numerical Simulation

H Zhang, Y Hou, K Wu, T Zhang, K Wu, X Zhang - Applied Sciences, 2019 - mdpi.com
The characteristics of series-flow between two consecutive tunnels with distance ranging
from 20 m to 250 m are explored by computational fluid dynamics (CFD) parametric …

Prediction of pollutant concentration and ventilation control in urban bifurcate tunnel, China

Q Li, C Chen, H Yuan, L Wang, S Xu, Y Li - Tunnelling and Underground …, 2018 - Elsevier
The changes in the complex structural features and traffic characteristics of urban bifurcate
tunnel have led to variation in the emission of pollutants and distribution of their …

Numerical research on the mixture mechanism of polluted and fresh air at the staggered tunnel portals

X Zhang, T Zhang, K Zhu, Z Huang, K Wu - Applied Sciences, 2018 - mdpi.com
In longitudinal ventilation, circulating air is formed in portals for closely spaced twin tunnels,
which causes mixing between the polluted air exhausted from one tunnel and the fresh air …

Complementary ventilation operational test in large longitudinal slope double-hole tunnel

W Ya-qiong, HU Yan-Jie, D Min… - 交通运输工程 …, 2014 - transport.chd.edu.cn
In order to solve the technical problem that whether ventilation shafts are needed to set up or
not in upstream tunnel when the air inflow and outflow are imbalanced in the large …

A uniform air flow distribution design strategy for use in tunnel transverse ventilation systems

M Wang, T Deng, L Yu, X Wang - Journal of Zhejiang University-SCIENCE …, 2019 - infona.pl
We focused mainly on a uniform air flow distribution design strategy for a multi-perforated air
supply duct with a multi-blade opposed regulation damper. This design is especially …