neutral-point-clamped PWM inverter. Utilizing the phase current polarity information, this
technique distributes the redundant voltage vectors in a manner to obtain stable neutral
point voltage under all operating conditions including the zero power factor condition.
Detailed analysis and computer simulations show the superiority of the proposed method.
The feasibility of the proposed method has been proven via laboratory experiments.