was found that the weldment failure in the peel test of the joints occurred through the weld
nugget. This is called an interfacial failure and is not acceptable because it is a sign of
insufficient mechanical strength. Investigation showed that this kind of fracture is attributed to
the brittleness of the nugget zone, caused by its martensitic microstructure due to the high
cooling rate in the welding. For eliminating this defect, resistance spot welding procedures …