Analysis of pump start-up transients

RB Grover, SM Koranne - Nuclear Engineering and Design, 1981 - Elsevier
… A computer programme has been developed to study pump start-up transients. Predictions of
… is low, pump speed goes marginally beyond the steady speed during the start-up transient. …

A model for the analysis of pump start-up transients in Tehran Research Reactor

K Farhadi, A Bousbia-Salah, F D'Auria - Progress in Nuclear Energy, 2007 - Elsevier
… (1) can be rewritten as:(3) 1 g ( ∑ L i A i ) ⅆ q ⅆ t = h p − q 2 q ( ss ) 2 h p ( ss ) The method
used in the present work for analysing pump start-up transients begins with prediction of …

The transient characteristics of a pump during start up

S Saito - Bulletin of JSME, 1982 - jstage.jst.go.jp
… relationship between the transient and steady … study, theoretical and experimental analyses
were carried out on a diffuser pump by varying three factors af— fecting the pump transient

Analysis of reactor coolant pump transient performance in primary coolant system during start-up period

H Gao, F Gao, X Zhao, J Chen, X Cao - Annals of Nuclear Energy, 2013 - Elsevier
… and pump transient performance, during start-up transients, is a very important factor in the
reactor coolant pumps … relation of the reactor coolant pump, the transient pump total head, the …

Phase classification and transient effects of the start-up process of multi-functional pump station in pump mode

X Zhang, G Pavesi, Z Xu, X Song, F Tang - Journal of Energy Storage, 2024 - Elsevier
… The occurrence phase of the transient effect during the SUP is analyzed, and the deviation
… the transient characteristics is revealed. In this study, the evaluation formula of the start-up

Numerical simulation and experimental study of transient characteristics in an axial flow pump during start-up

S Fu, Y Zheng, K Kan, H Chen, X Han, X Liang, H Liu… - Renewable Energy, 2020 - Elsevier
study have solved some key technical problems in transient simulation of the pump start-up
However, problems such as the compressibility of the fluid during the pump start-up [[37], [38]…

Model based analysis of the time scales associated to pump start-ups

A Dazin, G Caignaert, G Dauphin-Tanguy - Nuclear Engineering and …, 2015 - Elsevier
… flow rate, pipe lengths) on the intensity and duration of the transient effects during a start-up.
These analyses are made assuming non cavitating operation conditions. It is also assumed …

Theoretical prediction model of transient performance for a mixed flow pump under fast start-up conditions

M Liu, Y Han, L Tan, Y Lu, C Ma, J Gou - Physics of Fluids, 2023 - pubs.aip.org
… quickly and accurately predicting pump start-up performance makes it difficult to analyze the
pump transient performance under fast start-up conditions is established in the present study

Influence of pump starting times on transient flows in pipes

S Elaoud, E Hadj-Taïeb - Nuclear engineering and design, 2011 - Elsevier
study is the numerical modelling of the transient flow in a cylindrical pipe caused by the
start-up of a centrifugal pump. The … The results of this study have shown that the transient head …

Deep analysis of the transient behavior of centrifugal pumps during startup and shutdown

YL Zhang, YY Ji, YJ Zhao - Measurement and Control, 2022 - journals.sagepub.com
… is inevitable and its transient performance has thus attracted increasing attention in recent
years. This study aims to reveal the transient characteristics of centrifugal pumps during the …