In this work, we present a new experimental setup for the assessment of the anisotropic
properties of Bovine Pericardium (BP) membranes. The chemically fixed BP samples have
been subjected to a bulge test with in situ confocal laser scanning at increasing applied
pressure. The high resolution topography provided by the confocal laser scanning has
allowed to obtain a quantitative measure of the bulge displacement; after polynomial fitting,
principal curvatures have been obtained and a degree of anisotropy (DA) has been defined …
Abstract
In this work, we present a new experimental setup for the assessment of the anisotropic properties of Bovine Pericardium (BP) membranes. The chemically fixed BP samples have been subjected to a bulge test with in situ confocal laser scanning at increasing applied pressure. The high resolution topography provided by the confocal laser scanning has allowed to obtain a quantitative measure of the bulge displacement; after polynomial fitting, principal curvatures have been obtained and a degree of anisotropy (DA) has been defined as the normalized difference between the maximum and minimum principal curvatures. The experiments performed on the BP membranes have allowed us to obtain pressure-displacement data which clearly exhibit distinct principal curvatures indicating an anisotropic response. A comparison with curvatures data obtained on isotropic Nitrile Buthadiene Rubber (NBR) samples has confirmed the effectiveness of the experimental setup for this specific purpose. Numerical simulations of the bulge tests have been performed with the purpose of identifying a range of constitutive parameters which well describes the obtained range of DA on the BP membranes. The DA values have been partially validated with biaxial tests available in literature and with suitably performed uni-axial tensile tests.
The American Society of Mechanical Engineers
以上显示的是最相近的搜索结果。 查看全部搜索结果