reported at temperatures from 303 to 423 K and pressures up to 50 MPa. The binary mixture
was studied at three compositions, and measurements on pure 1-hexanol are also reported.
The two properties were measured simultaneously using a single vibrating-wire sensor. The
present results for density have a precision of±0.07% and an estimated uncertainty of±0.3%.
The viscosity measurements have a precision of±1% and an estimated uncertainty of±4 …