Dynamic measurement of patellofemoral kinematics and contact pressure after lateral retinacular release: an in vitro study

S Ostermeier, M Holst, C Hurschler… - Knee Surgery, Sports …, 2007 - Springer
S Ostermeier, M Holst, C Hurschler, H Windhagen, C Stukenborg-Colsman
Knee Surgery, Sports Traumatology, Arthroscopy, 2007Springer
The purpose of this study was to investigate the influence of lateral retinacular release and
medial and lateral retinacular deficiency on patellofemoral position and retropatellar contact
pressure. Human knee specimens (n= 8, mean age= 65 SD 7 years, all male) were tested in
a kinematic knee-simulating machine. During simulation of an isokinetic knee extension
cycle from 120° to full extension, a hydraulic cylinder applied sufficient force to the
quadriceps tendon to produce an extension moment of 31 Nm. The position of the patella …
Abstract
The purpose of this study was to investigate the influence of lateral retinacular release and medial and lateral retinacular deficiency on patellofemoral position and retropatellar contact pressure. Human knee specimens (n = 8, mean age = 65 SD 7 years, all male) were tested in a kinematic knee-simulating machine. During simulation of an isokinetic knee extension cycle from 120° to full extension, a hydraulic cylinder applied sufficient force to the quadriceps tendon to produce an extension moment of 31 Nm. The position of the patella was measured using an ultrasound based motion analysis system (CMS 100®, Zebris). The amount of patellofemoral contact pressure and its pressure distribution was measured using a pressure sensitive film (Tekscan®, Boston). Patellar position and contact pressure were first investigated in intact knee conditions, after a lateral retinacular release and a release of the medial and lateral retinaculum. After lateral retinacular release the patella continuously moved from a significant medialised position at flexion (P = 0.01) to a lateralised position (P = 0.02) at full knee extension compared to intact conditions, the centre of patellofemoral contact pressure was significantly medialised (0.04) between 120° and 60° knee flexion. Patellofemoral contact pressure did not change significantly. In the deficient knee conditions the patella moved on a significant lateralised track (P = 0.04) through the entire extension cycle with a lateralised centre of patellofemoral pressure (P = 0.04) with a trend (P = 0.08) towards increased patellofemoral pressure. The results suggest that lateral retinacular release did not inevitably stabilise or medialise patellar tracking through the entire knee extension cycle, but could decrease pressure on the lateral patellar facet in knee flexion. Therefore lateral retinacular release should be considered carefully in cases of patellar instability.
Springer
以上显示的是最相近的搜索结果。 查看全部搜索结果

Google学术搜索按钮

example.edu/paper.pdf
搜索
获取 PDF 文件
引用
References