Energy Expenditure Prediction Using Raw Accelerometer Data in Simulated Free Living.

AH Montoye, LM Mudd, S Biswas… - Medicine and science in …, 2015 - europepmc.org
Medicine and science in sports and exercise, 2015europepmc.org
Purpose The purpose of this study was to develop, validate, and compare energy
expenditure (EE) prediction models for accelerometers placed on the hip, thigh, and wrists
using simple accelerometer features as input variables in EE prediction models. Methods
Forty-four healthy adults participated in a 90-min, semistructured, simulated free-living
activity protocol. During the protocol, participants engaged in 14 different sedentary,
ambulatory, lifestyle, and exercise activities for 3-10 min each. Participants chose the order …
Purpose
The purpose of this study was to develop, validate, and compare energy expenditure (EE) prediction models for accelerometers placed on the hip, thigh, and wrists using simple accelerometer features as input variables in EE prediction models.
Methods
Forty-four healthy adults participated in a 90-min, semistructured, simulated free-living activity protocol. During the protocol, participants engaged in 14 different sedentary, ambulatory, lifestyle, and exercise activities for 3-10 min each. Participants chose the order, duration, and intensity of activities. Four accelerometers were worn (right hip, right thigh, as well as right and left wrists) to predict EE compared with that measured by the criterion measure (portable metabolic analyzer). Artificial neural networks (ANNs) were created to predict EE from each accelerometer using a leave-one-out cross-validation approach. Accuracy of the ANN was evaluated using Pearson correlations, root mean square error, and bias. Several ANNs were developed using different input features to determine those most relevant for use in the models.
Results
The ANNs for all four accelerometers achieved high measurement accuracy, with correlations of r> 0.80 for predicting EE. The thigh accelerometer provided the highest overall accuracy (r= 0.90) and lowest root mean square error (1.04 METs), and the differences between the thigh and the other monitors were more pronounced when fewer input variables were used in the predictive models. None of the predictive models had an overall bias for prediction of EE.
Conclusions
A single accelerometer placed on the thigh provided the highest accuracy for EE prediction, although monitors worn on the wrists or hip can also be used with high measurement accuracy.
europepmc.org
以上显示的是最相近的搜索结果。 查看全部搜索结果