Impact of timing of device removal on mortality in patients with cardiovascular implantable electronic device infections

KY Le, MR Sohail, PA Friedman, DZ Uslan, SS Cha… - Heart Rhythm, 2011 - Elsevier
KY Le, MR Sohail, PA Friedman, DZ Uslan, SS Cha, DL Hayes, WR Wilson, JM Steckelberg…
Heart Rhythm, 2011Elsevier
BACKGROUND: Cardiovascular implantable electronic device (CIED) infections are
associated with increased mortality. However, detailed analyses of the impact of device
removal on mortality have been limited. OBJECTIVE: This study sought to evaluate the
impact of timing device removal on mortality in patients with CIED infections. METHODS: We
retrospectively reviewed all cases of CIED infections seen at Mayo Clinic Rochester
between 1991 and 2008. The impact of device removal on 30-day and 1-year mortality was …
BACKGROUND
Cardiovascular implantable electronic device (CIED) infections are associated with increased mortality. However, detailed analyses of the impact of device removal on mortality have been limited.
OBJECTIVE
This study sought to evaluate the impact of timing device removal on mortality in patients with CIED infections.
METHODS
We retrospectively reviewed all cases of CIED infections seen at Mayo Clinic Rochester between 1991 and 2008. The impact of device removal on 30-day and 1-year mortality was evaluated using Cox proportional hazards models.
RESULTS
Of 416 patients with CIED infection, 23 (5.5%) died by 30 days and 61 (14.6%) died by 1 year. Forty-four (12.0%) developed complications related to device removal, and 3 (0.8%) died. Complete procedural success was achieved in 341 (81.9%) and clinical success in 391 (93.9%) cases. In multivariate analysis, antimicrobial therapy without device removal was associated with a 7-fold increase in 30-day mortality (hazard ratio [HR] 6.97, 95% confidence interval [CI] 1.36 to 35.60). Although device removal complications were associated with increased mortality at 30 days (HR 4.33, 95% CI 1.47 to 12.70) and at 1 year (HR 3.77, 95% CI 1.88 to 7.55), immediate device removal, when compared to delay in device removal in favor of initial conservative therapy with antimicrobials alone, and no device removal, was associated with a 3-fold decrease in 1-year mortality (HR 0.35, 95% CI 0.16 to 0.75).
CONCLUSION
Although device removal resulted in fatal complications in a few patients, the mortality associated with a delay in device removal was significantly higher. Therefore, early and complete device removal was associated with improved outcomes.
Elsevier
以上显示的是最相近的搜索结果。 查看全部搜索结果

Google学术搜索按钮

example.edu/paper.pdf
搜索
获取 PDF 文件
引用
References