Spontaneous ignition of coal dust deposited on a flat hot surface (1D case) and trapped
between two hot surfaces (2D geometry), forming the shape of a wedge, is analyzed using
lab-scale experiments and a mathematical model. The solution is obtained by assuming a
temperature polynomial of third (one-dimensional) and fifth order (two-dimensional), in the
energy conservation equation where the source term is defined using a 1-step Arrhenius …