Linac4 technical design report

L Arnaudon, M Magistris, M Paoluzzi, M Hori, D Küchler… - 2006 - cds.cern.ch
… The design and construction of a new source requires a long development time, and it … the
conservative approach for Linac4 is to copy an existing successful source design close to our …

submitter: Linac4 design report

C Martin, S Mathot, C Rossi, N Dos Santos, T Zickler… - 2020 - cds.cern.ch
Linac4 includes transfer and measurement lines up to the PSB injection, where the ions are
stripped of their two electrons to leave only protons. Linac4Linac4 will be connected to the …

[PDF][PDF] Linac4 Technical Design Report

S Cousineau - 2006 - academia.edu
… The design and construction of a new source requires a long development time, and it … the
conservative approach for Linac4 is to copy an existing successful source design close to our …

The Linac4 project

A Lombardi - 2016 - cds.cern.ch
… In particular in the framework of Linac4 we have developed the “forward-method” [13] which
extends the accuracy of the classic emittance reconstruction techniques to space charge …

[PDF][PDF] Linac4 commissioning status and challenges to nominal operation

G Bellodi, L Team - Proc. HB'18, 2018 - accelconf.web.cern.ch
Linac4 is presently undergoing a reliability and beam quality test run to meet the beam …
achieving nominal operation and we will report on the commissioning steps still needed for final …

[HTML][HTML] Technical design and concept of a 0.35 T MR-Linac

S Klüter - Clinical and translational radiation oncology, 2019 - Elsevier
… This work summarizes the technical design of a 0.35 T MR-Linac and corresponding clinical
concepts. The system facilitates 3D-conformal as well as IMRT treatments with 6MV photons…

Linear accelerator test facility at LNF conceptual design report

P Valente, M Belli, B Bolli, B Buonomo… - arXiv preprint arXiv …, 2016 - arxiv.org
Test beam and irradiation facilities are the key enabling infrastructures for research in high
energy physics (HEP) and astro-particles. In the last 11 years the Beam-Test Facility (BTF) of …

PERLE. Powerful energy recovery linac for experiments. Conceptual design report

D Angal-Kalinin, G Arduini, B Auchmann… - Journal of Physics G …, 2018 - iopscience.iop.org
… A suitable configuration derived from the here presented design concept may next be moved
forward to a technical design and possibly be built by an international collaboration which …

Alignment and field error tolerance in Linac4

G Bellodi, M Garcia Tudela, AM Lombardi, P Posocco… - 2011 - cds.cern.ch
LINAC4 is about 80 m long, normal-conducting, and will be … The location has been chosen
to allow using LINAC4 as the first … and the final tolerances for all the elements of LINAC4. …

[PDF][PDF] Linac4: Progress on Hardware and Beam Commissioning

AM Lombardi - 2015 - cds.cern.ch
Linac4 has been commissioned, with a temporary source, up … In this talk we will present
the status of the Linac4 beam … 50 MeV proton beam from Linac4 will be discussed together …