Measurement of local gas holdup in bubble columns via a non-isokinetic withdrawal method

S García-Salas, C Orozco-Alvarez, RM Porter… - Chemical engineering …, 2005 - Elsevier
Chemical engineering science, 2005Elsevier
An inexpensive method was developed to measure local gas holdup based on withdrawal of
the air–liquid dispersion in bioreactors under non-isokinetic conditions. The method was
tested with several suction probe designs and withdrawal pressures using coalescing and
non-coalescing model media as well as during yeast fermentations. Simultaneously, gas
holdup was measured manometrically. With a straight end probe and vacuum pressure of
3kPa, local gas holdup measurements presented a relative error< 6% compared to the …
An inexpensive method was developed to measure local gas holdup based on withdrawal of the air–liquid dispersion in bioreactors under non-isokinetic conditions. The method was tested with several suction probe designs and withdrawal pressures using coalescing and non-coalescing model media as well as during yeast fermentations. Simultaneously, gas holdup was measured manometrically. With a straight end probe and vacuum pressure of 3kPa, local gas holdup measurements presented a relative error <6% compared to the manometric method, independently of the media composition. This method was used to characterize local gas holdup in a bubble column. Two new parameters are proposed to characterize non-gassed volume and gas holdup homogeneity.
Elsevier
以上显示的是最相近的搜索结果。 查看全部搜索结果