A three-dimensional multi-electrode array for multi-site stimulation and recording in acute brain slices

MO Heuschkel, M Fejtl, M Raggenbass… - Journal of neuroscience …, 2002 - Elsevier
… Several multi-electrode array devices integrating planar metal electrodes … multi-electrode
arrays. The electrical differences between planar and 3D protruding electrode configuration

Effect of multi-electrode configuration on sensitivity to interaural timing differences in bilateral cochlear-implant users

A Kan, HG Jones, RY Litovsky - The Journal of the Acoustical Society …, 2015 - pubs.aip.org
… stimulation may lead to poorer overall performance due to interference from places with
poor ITD sensitivity, or from channel interaction due to electrical current spread. Alternatively, …

Design and fabrication of a three-dimensional multi-electrode array for neuron electrophysiology

L Zuo, S Yu, CA Briggs… - Journal of …, 2017 - asmedigitalcollection.asme.org
Neural recording and stimulation with high spatial and temporal resolution are highly desirable
in the study of neurocommunication and diseases. Planar multiple microelectrode arrays (…

Multi-electrode arrays: Enhancing traditional methods and enabling network physiology

J Whitson, D Kubota, K Shimono, Y Jia… - … : Using Multi-Electrode …, 2006 - Springer
Early research in the field of multi-electrode arrays (MEAs) was largely concerned with the
development of MEA hardware (see Chapter 1 for a review). This research lay the ground …

Multi-electrode detection in voltammetryPart I. A versatile multi-channel voltammetric instrument

JJR Rohwedder - Analyst, 1998 - pubs.rsc.org
… The present configuration allows single- and multichannel electrochemical techniques to
be performed using the same array of electrodes. In the multi-channel ES approach, each …

Multi-electrode stimulation and recording in the isolated retina

AE Grumet, JL Wyatt Jr, JF Rizzo III - Journal of neuroscience methods, 2000 - Elsevier
… A custom interface written in MATLAB was used to generate stimulation waveforms, to
display and analyze the eight-channel data, and to control amplifier channel settings. …

Multi-electrode array technologies for neuroscience and cardiology

ME Spira, A Hai - Nature nanotechnology, 2013 - nature.com
… –electrode configuration used in this work, made it possible, for the first time, to record
with a MEA action potentials as well as synaptic potentials (Fig. 5c). The key to the multi-electrode-…

[HTML][HTML] Impact of micro-, mini-and multi-electrode mapping on ventricular substrate characterisation

B Berte, K Zeppenfeld, R Tung - Arrhythmia & electrophysiology …, 2020 - ncbi.nlm.nih.gov
… During substrate-based ablation techniques, wide practice variations exist with mapping
via dedicated multi-electrode catheter or conventional ablation catheters. Recently, newer …

Use of multi-electrode array recordings in studies of network synaptic plasticity in both time and space

MG Liu, XF Chen, T He, Z Li, J Chen - Neuroscience bulletin, 2012 - Springer
Simultaneous multisite recording using multi-electrode arrays (MEAs) in cultured and
acutely-dissociated brain slices and other tissues is an emerging technique in the field of network …

A multi-electrode array for combined microiontophoresis and multiple single-unit recordings

S Haidarliu, D Shulz, E Ahissar - Journal of neuroscience methods, 1995 - Elsevier
… in the plasticity of functional connectivity of local cortical circuits, we developed a multi-electrode
array for combined … Second, we prepared a setup in which one of the TEs (electrode …